Installing the S8700 IP Connect
May 2002
Installing the Avaya G600 Media
Gateway
Floor plans and equipment layouts for typical system installations are provided in the Overview
of the Avaya S8700 Media Server for IP Connect Configurations.
Avaya G600 Media Gateways are typically installed in the same equipment room as the Avaya
S8700 Media Server rack hardware; however, they can be installed in another location,
including another state or country. A port network consists of up to 4 G600 Media Gateway in a
rack, with the media gateway in the A location (bottom of rack) being the one containing the
TN2312AP IP Server Interface (IPSI) circuit pack.
NOTE:
Before you begin the installation, check the location of the AC/DC power receptacles. The
receptacles must be on separately fused circuits not controlled by wall switches. They
must be located within 10 feet (3 meters) of the rack and outside the Main Distribution
Frame (MDF) area.
NOTE:
For convenience, we recommend installing the reference IPSI, the one associated with the
license file, in a port network in the same room as the control network hardware.
‘‘Avaya G600 Media Gateways installed next to the media server rack’’ on page 40
shows a
typical Avaya S8700 Media Server for IP Connect Configurations installation.