EasyManua.ls Logo

Avaya S8700 - Wire the 1146 B2 Power Distribution Unit

Avaya S8700
212 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
154
Installing the S8700 IP Connect
May 2002
Wire the 1146B2 Power Distribution Unit
Wire endpoints to the 1146B2 while power from the 1145B2 is on. A red LED lights if its
associated circuit is connected to shorted wiring or to a shorted telephone.
1 Install cross-connect jumpers to wire from the unit (the label shows polarity) to Pins 7
and 8 of the appropriate information outlet. Route the wires through the clip provided on
the unit. If a red LED is on, see ‘‘Reset LEDs on Power Distribution Unit’’ on page 155
.
See ‘‘Typical Wiring to a Telephone’’ on page 154
.
2 Mark lead destinations on the label next to each connector. Also mark the Unit Number
and Connectivity information on the label.
Typical Wiring to a Telephone
3
4
5
1
11
2
7
12
13
14
6
8
9 9
10
14
Figure notes
1 Power Supply Kit
2 2.5, 5.0, or 8.0 Amp Hour Battery
3 1146B2 Distribution Unit
4 1145B2 Power Supply
5 Circuits 1-16
6 Circuits 17-32
7 Port Circuit
8 Main Distribution Frame
9 Modular Cord
10 Pins 7 and 8 (Display Terminal
Power)
11 AC Input
12 Installer-Provided Ground Wire
13 ISDN/ Display System Protocol
Terminal
14 Circuits 1-32

Table of Contents