Overview of Commands
MDSC-1119 and MDSC-2124_________________________________________________________________11
4.4.2.
INPA
This command allows the user to enter or read an alias name for the current input.
Command Input Type Alias Name
CMD 1 – max number of
inputs available
Alias Name
RV
MM
Mm
INPA
CMD
Sets the alias name
Example: CMD,INPA,1,Camera1
Response: 0:Camera1
RV
Reads the currently selected alias name.
Example: RV,INPA,1
Response: 0:Camera1
MM
Returns the maximum number of characters in the alias name.
Example: MM,INPA
Response: 12
Mm
Returns the minimum number of characters in the alias name.
Example: Mm,INP
Response: 0
4.5.
Adjustments commands
The following commands give you comparable to control as with the Adjustments menu
in the OSD.
4.5.1.
BRI
Adjusts and gets information about the brightness of the display.
Command Minimum to Maximum Brightness
CMD 0 - 200
RV
MM
Mm
BRI
CMD
Sets brightness value
Example: CMD,BRI,50
Response: 50