Overview of Commands
MDSC-1119 and MDSC-2124_________________________________________________________________39
• RV
Reads the GPIO position
Example: RV,GPIOP,1
Response: 1
• MM
Returns maximum GPIO position
Example: MM,GPIOP
Response: 6
• Mm
Returns minimum GPIO position
Example: Mm,GPIOP
Response: 1
4.9.12.
GPIOTR
This command selects trigger settings pulse/level for GPIO inputs.
Command Image Trigger Number Resulting Trigger
Level
CMD
1 / 2
0
1
Level
Pulse
RV 1 / 2
MM
Mm
GPIOTR
• CMD
Sets the GPIO trigger value
Example: CMD,GPIOTR,1,1
Response: 1
• RV
Reads the GPIO trigger value
Example: RV,GPIOTR,1
Response: 1
• MM
Returns maximum GPIO trigger value
Example: MM,GPIOTR
Response: 1
• Mm
Returns minimum GPIO trigger value
Example: Mm,GPIOTR
Response: 0
4.9.13.
BAUD
This command selects the RS232 baud rate values for RS232 communication.
*Note: Changing the baud rate of the display will also require a change of baud rate on