Field Service Manual December 2003
Page 147 of 276
37 Acceleration feedforward: 128
determines the acceleration power
38 Velocity feedforward: 18
determines the speed-dependent power
Parameter ver 8.0 your choice: T
It is possible to fill in 2 reference thicknesses. These reference
thicknesses have a corresponding parameter list in option "M" for the
frequencies and delays. For film types with a thickness different from the
reference thickness an interpolation is made for the parameters in option
"M".
Parameter ver 8.0 your choice :
Reference thicknesses 1/10mil
Thickness[0] = 70 :
Thickness[1] = 40 :
Thickness per filmtype in 1/10 mil
Ftype 0 --> 70 Ftype 1 --> 70
Ftype 2 --> 70 Ftype 3 --> 70
Ftype 4 --> 70 Ftype 5 --> 70
Ftype 6 --> 40 Ftype 7 --> 40
Ftype 8 --> 40 Ftype 9 --> 40
Ftype 10 --> 40 Ftype 11 --> 40
[ Q to quit ]
V8.0 Ftype :
Parameter ver 8.0 your choice: M
By choosing M all frequencies and beam delays are displayed
on the screen for a shuffle pattern that is interlaced (distance
between the beams is always twice the resolution). This is the
shuffle pattern that is used during exposure!!!!
The M parameters are independent from the number of beams,
resolution,
shrx, shry,...
The M parameters are recalculated
There are separate Frequency and delay tables for the 2 reference
thicknesses. Fill in the values for the reference thickness in option
"T" before calling up the frequency and delay table in option "M"
Parameter ver 8.0 your choice : M
Frequency and delay table for 70 or 40 1/10mil thickness ? 70
Add frequency corrections due to knife calibrator ? (y/n)n
The corrections are added to the frequency table. Is
used when you want to recalibrate the knife (Be sure
that the testjobs exposed with SSIPRO are OK)
Reset frequency corrections due to knife calibrator to zero ? (y/n)n
The corrections are set to zero before you calibrate the knife