MX08 Multichannel Weighing System, Technical Manual, Rev. 2.5 Page 69 of 144
The meanings of the annunciater LEDs in operation are given below.
LED
Symbol Name
Pwr Power
MX08 PB not powered. Check power cable.
MX08 PB powered.
Lnk Link
No data transmission done.
Data transmission done to xFace or Profibus
Err Error
No Error found.
Error: Look at the error table in Section 8.6.
Blank Light Flash Blank for 0.3 second
Table 8.1 - Annunciater LEDs
ST Status LED
State
Indication
Comment
Off Not power or not initialized
No power or profibus module
is in initialization state
Green
Initialized
Flashing Green
Initialized, diagnostic event(s)
present
Diagnostic is active
Red
Exception error
There is an exception error
OP Operation mode LED
State
Indication
Comment
Off
Not online /No power
Check power and cable
Green
On-line, data exchange
-
Flashing Green
On-line, clear
-
Flashing Red
(2 flash)
PROFIBUS configuration error Check GSD file configuration.

Table of Contents