MX08 Multichannel Weighing System, Technical Manual, Rev. 2.5 Page 83 of 144
24V 0V
Figure 9.3 - Pin layout of MX08 PN 24 VDC connector
10.3. N-Bus Addressing
MX08 instruments communicate each other over internal data bus which is called N-Bus.
MX08 gateway instrument is master of N-Bus. All other instruments are slave and shall be
addressed to gateway.
N-Bus addressing can be done by using xFace PC software (Refer to Section 3.3) or via
programming switch (Section 3.9).
10.4. MX08 PN Setup
MX08 gateway set up is done by xFace software as described in this section. Connect
MX08 PN instrument to your PC via RS-232C service port on the instrument as indicated
in Figure 9.2.
Select Gateway tab after connecting xFace to MX08 PN. Gateway tab is seen in figure
below. You will see the gateway information and Profinet parameters in this tab.
Figure 9.4 - Profinet setup