MX08 Multichannel Weighing System, Technical Manual, Rev. 2.5 Page 72 of 144
Figure 8.4 - Profibus DP setup
9.4.1. Profibus DP Parameters
There is only one parameter for Profibus network.
Profibus Rack Address
The address range is 1 to 126.
Default is ‘01’.
9.4.2. Profibus Information
xFace Gateway information block in Gateway tab allows the user to know much
information about gateway instrument as in the following;
Field bus: Profibus DP
Firmware Version: Revision number of firmware
Firmware Date: Generated firmware date
Hardware Version: Revision number of main pcb board.
Serial Number: Instrument’s serial number.
Gateway Status: Follow the status whether the system is proper or not.
GSD Configuration: Max. quantity of MX08 AD and MX08 IO instruments in the system.