EasyManua.ls Logo

BAYKON MX08 - Page 96

BAYKON MX08
148 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MX08 Multichannel Weighing System, Technical Manual, Rev. 2.5 Page 94 of 144
Figure 10.3 - Cross cabling PC connection
MX08 EN serial interface connections are shown below:
Figure 10.4 - MX08 EN serial interface connections
RS-232C Serial interface
Usage
Interfacing with PC and PLC, programming the MX08 (xFace)
Data formats
BSI, Modbus RTU High-Low, Modbus RTU Low-High
Baud rate
9600 bps
Length and parity
8 bit no parity
Start / Stop bits
1 start bit and 1stop bit
Ethernet interface
Usage
Ethernet interface with PC or PLC
Data formats
BSI, Modbus TCP/IP High-Low, Modbus TCP/IP Low-High
Ethernet
The Ethernet interface operates at 10 Mbit, half duplex
Warning: Connect the shield to the reference ground or shield pin of the power connector.
Warning: Disconnect xFace PC software for Ethernet interfacing.
Power Supply Connection
The pin configuration of the 24 VDC power supply connector located on front bottom of the
instrument is shown in figure below. Proper grounding is very important for the accuracy
and the safety of your measuring system. Before interfering the instrument, please turn off
the power and wait at least for 30 seconds.
Warning: Connect the grounding terminal to the reference ground.

Table of Contents