Attributes-Autobypass with Reset Zones with this
attribute will be bypassed automatically, if violation oc
-
curs during Arming procedure of their Partitions. They
will be unbypassed when standby is restored.
Behaviour-Mode The Zones can be used for system
monitoring (Alarm Zones), or management (Command
Zones).
+
The Wireless Zones CANNOT be Command
Zones.
r
Alarm Event — If Alarm conditions are detected, the
Alarm Zones will generate the respective event (refer
to “Type”). The Events-Action page will allow you to
associate each event with one or more actions (acti
-
vation of Outputs, Digital Communicator, Dialler,
etc.). The system cannot generate an Alarm event until
the Partitions the Zone is assigned to Arm (refer to
“Partitions”).
+
This does not apply to 24h and Fire Zone events,
as these events do not depend on Partition status.
If the zone is NOT an Exit Delay or Last Exit Zone (re
-
fer to “Type”) the Control Panel will start monitoring as
soon as the Partitions the Zone is assigned to Arm, oth
-
erwise, it will start monitoring when the longest Exit De-
lay of the Armed Partitions the Zone is assigned to ends
(refer to “Partitions”).
Each Alarm Zone can generate the Zone Alarm event for
the programmed number of times (refer to “Cycles”).
r Command — Each Command Zone can be pro-
grammed to activate one of the following actions:
Ø Arm Only
Ø Disarming
Ø Arm/Disarm
Ø
Arm Swtich
Ø
Clear Call Queue
Ø
Alarm Reset
The Command Zones will activate when they are unbal
-
anced (refer to “Balance”) for the programmed number
of times or length of time (refer to “Sensitivity”).
3
In order to comply with EN50131 Grade 3 stan
-
dards, Command Zone Balance must be Triple
End of Line and Control Devices must be Grade 3.
Behaviour-Command Type If a Command Zone trig
-
gers an Alarm (see “Balance" and “Sensitivity”), the
system will generate the programmed Actions. In all
other cases (Tamper and Short Circuit) it will operate as
an Alarm Zone.
Command Zones will be active at all times, regardless
of the status of their Partitions (Armed/Disarmed).
r
Arm Only — If this command is selected, all the Par
-
titions the Zone is as signed to will Arm when the
Zone triggers an Alarm.
r
Disarming — If this command is selected, all the
Partitions the Zone is as signed to will Disarm when
the Zone triggers an Alarm.
r
Arm Disarm — If this command is selected, all the
Partitions the Zone is assigned to will Arm — when
the Zone triggers an Alarm, and Disarm — when it
restores to standby.
r
Arm Switch — When the zone is activated its Parti
-
tions change status: the armed Partitions are dis
-
armed; the disarmed Partitions are armed.
+
Partitions — Armed by an Arm Disarm Command
Zone — cannot be Disarmed until all the Zones of
that type are in standby status (and CANNOT be
Disarmed via Keypad, Reader, Telephone or PC).
r
Behaviour-Clear Call Queue — If this option is en
-
abled, the Call Queue will be cleared when the Zone
triggers an Alarm for all the event associated to the
partition assigned to the zone. If the zone is Enabled
over all area, when the zone is violated, also the sys
-
tem call(s) will be cleared.
r
Behaviour-Alarm Reset — If this option is enabled,
all the Partitions the Zone is assigned to will Reset
when the Zone triggers an Alarm.
Options-In And Group If this option is enabled, the
Partition the zone is assigned to goes in alarm when an-
other Partition Zone with this option enabled goes in
alarm before a 30 minute window expires.
Any time the Partition is armed the AND zone timer is
reset to zero.
If any zone with this option enabled, is violated while the
timer is NOT running:
Ø
the timer starts with a fixed value of 30 minutes;
Ø
the Partition alarm is NOT generated;
Ø
the zone alarm is NOT logged;
Ø
the zone which started the timer is stored.
If the same zone is violated again while the timer is running:
Ø
the zone alarm is NOT logged;
Ø
the timer is restarted.
If another Partition Zone with this option enabled, is vio
-
lated while the timer is running:
Ø
the zone alarm is logged;
Ø
the Partition alarm is generated;
Ø
the timer restarts again.
If the timer expires:
Ø
the timer expired event is logged.
ABSOLUTA PROGRAMMING FROM THE PC 47