Caller ID over GSM events
These events (Table 16) occur when the GSM Module
receives a call from the respective telephone number,
as long as the Caller ID over GSM option for the tele
-
phone number is ENABLED (see the Phonebook op
-
tion group).
When the control panel receives the call from the tele
-
phone number, it hang up after a few rings and per
-
forms the programmed actions: then the control panel
confirms this by ringing the telephone number, if the
Ringback Enabled option is ENABLED.
+
The ringback for confirmation may be delayed if there
are other calls in the queue or may be lost if the queue
is full or because of problems on the GSM network.
Ringback Enabled If disabled (default), the event will
NOT ring back for confirmation.
If ENABLED, the event will ring back for confirmation.
n
Default settings
The default settings for the Events and Actions Option
Group are made to provide a control panel that can be
immediately operative with a minimum setup, as indi
-
cated on Table 9: the events listed on the EVENTS col
-
umn, activate the Outputs shown on the FIRST OUTPUT
column and send the Vocal Messages composed by the
Messages shown on the MESSAGE VIA TELEPHONE,
to ALL Voice Dialer numbers in the Phonebook.
A
In order to comply with the EN50131-1 and
EN50131-3 standards, the First Output, Third
Message and Telephone Enabled, about events
on the Table 9, should NOT be modified, only the
Telephone Enabled option relevant to the Gen
-
eral System Tamper event can be modified.
ABSOLUTA PROGRAMMING FROM THE PC 63
EVENTS
STATUS
FIRST OUTPUT
MESSAGE VIA TELEPHONE
Telephone Enabled
FIRST MESS.
SECOND MESSAGE THIRD MESSAGE
Zone Alarm (Hold-up) ON
—1
2 (Alarm) 14 (Hold Up in progress)
Yes
OFF 5 (Alarm Restoral)
General System Alarm ON
11
2 (Alarm)
Yes
OFF 5 (Alarm Restoral)
General System Tamper ON
21
3 (Tamper)
Yes
OFF 6 (Tamper Restoral)
Warning Low Battery on
Wireless Detector
ON
—1
4 (Fault) 12 (Wireless Batteries)
Yes
OFF 7 (Fault Restoral)
Warning Mains Failure ON
—1
4 (Fault) 10 (Main AC)
Yes
OFF 7 (Fault Restoral)
Warning Low Battery ON
—1
4 (Fault) 11 (Panel Battery)
Yes
OFF 7 (Fault Restoral)
Battery Power Trouble ON
—1
4 (Fault) 11 (Panel Battery)
Yes
OFF 7 (Fault Restoral)
System Fault ON
3— No
OFF
Automatic Arming Refused ON
—1
8 (General Activation) 13 (Auto arming failed)
Yes
OFF 9 (Restore General Activation)
Tamper on Armed System ON
11
3 (Tamper)
Yes
OFF 6 (Tamper Restoral)
Table 9 Default settings for the Events and Actions Option Group: Output nr. 1 is assigned to terminals NC, COM, NO,
+A and +N on the Main Board; Outputs nr. 2 and 3 are, respectively, assigned to terminals O1 and O2 on the Main Board.
Message no. 1 is the Panel Header (see Voice Message options group).