64 Expandable Hybrid Control Panel
EVENTS OCCURS WHEN... ENDS WHEN...
Alarm on zone ... the zone detects Alarm conditions
11
. ... the zone restores to standby status.
Tamper on zone ... the zone detects Tamper conditions
11
. ... Tamper conditions are no longer present on
the zone.
Real time of
Zone
... the voltage (resistance) on the Zone enters
the Alarm Range.
... voltage (resistance) on the Zone restores
to Standby Range.
Bypass Zone ... the Zone is bypassed. ... the Zone is restored.
Loss of
Wireless Zone
... the Wireless Detector fails to send a valid
signal during the Supervision Time.
... the Wireless Detector sends a valid signal
during the Supervision Time.
Device
Low Battery
... the battery of the Wireless Detector is low. ... the battery of the Wireless Detector is
charged.
Table 10 Zone Events.
EVENTS OCCURS WHEN... ENDS WHEN...
Generic alarm
on partition
... a Zone (any type) — associated with the Par
-
tition detects Alarm conditions.
... ALL Alarm events generated by Zones — as
-
sociated with the Partition restore to standby.
Tamper alarm
on partition
... a Zone — associated with the Partition de
-
tects Tamper conditions .
... ALL Tamper events generated by Zones —
associated with the Partition restore to standby.
Fire Alarm on
partition
... a Zone — associated with the Partition de
-
tects a Fire Alarm condition.
... ALL Fire Alarm events generated by Zones
associated with the Partition restore to standby.
Memory Alarm
on Partition
... the Generic alarm on partition Event oc
-
curs.
... the Partition Resets.
Alarm Stop on
Partition
... a Stop Alarms request is made using a User
PIN enabled for the Partition.
... the Control panel exits the Stop Alarms sta
-
tus.
Global Arming
Partition
... the Partition Arms in Away Mode. ... the Partition Arms in Stay Mode or Stay
Mode with Zero Delay.
Partial Arming
Partition
... the Partition Arms in Stay Mode or Stay
Mode with Zero Delay.
... the Partition Arms in Away Mode or Dis-
arms.
Autoarming
Warning
Partition
... there are 10 minutes left before automatic
arming of the partition.
SPOT EVENT!
Arming Refused
on Partition
... a request of Arming on the partition was re-
fused due to block condition.
SPOT EVENT!
Automatic
Arming Refused
on Partition
... during auto-arming, a Partition's zone is on
alarm. At default, the Panel must inhibit the
arming without activating the alarm.
SPOT EVENT!
Disarming
Partition
... the Partition Disarms. ... the Partition Arms in Away Mode or Stay
Mode or Stay with Zero Delay Mode.
Schedule on
Partition
... the scheduler arms the partition. ...the scheduler disarms the partition.
Entry Time on
Partition
... one of the Entry delay Zones belonging to
the Partition detects Alarm conditions and the
Partition is Armed in Stay or Away Mode.
... the Partition Entry Time expires or the Parti
-
tion Disarms.
Exit Time on
Partition
...the Partition Arms in Stay or Away Mode. ... the Partition Exit Time expires.
Chime on
Partition
... a Zone with the Chime option belonging to
the Partition detects Alarm conditions when the
Partition is Disarmed.
SPOT EVENT!
Delinquency on
Partition
... the Inactivity Time expires. SPOT EVENT!
Negligence on
Partition
... the Negligence Time expires. SPOT EVENT!
Reset on
Partition
... Alarms Reset is requested using a User PIN
and Keypad jointly enabled for the Partition.
SPOT EVENT!
Table 11 Partition Events
11Zones go into Alarm and Tamper status depending on the settings of the Zone Option Group.