SMS Fault Tel Number Select the Phone Numbers in
the Phonebook to which the message typed in the op
-
tion SMS Fault Text should be sent.
n
Pay As You Go
+
The pre-paid SIM CARD credit management ser
-
vice may be suspended at any time, at the discre
-
tion of each individual GSM network operator.
This section can be used to send an SMS providing credit
balance information (supplied by the operator) to the first
number in the phonebook at regular intervals. Set the fol
-
lowing options for a correct credit balance check request,
in accordance with the type of operator used.
Enquire Type Select the enquiry type (SMS, Call,
Service Command).
Enquire Number Type the phone number to call or to
which an SMS message should be sent in order to re
-
quest credit balance information.
Balance Message Type the string used to send SMS
messages and to make requests via service com
-
mands.
The table below shows the values for the above options
for some Italian mobile phone companies.
Options Vodafone Wind TIM
Enquire
Type
Call
Service
Command
SMS
Enquire
Number
404 40916
Balance
Message
*123# PRE CRE SIN
Enquire Interval Set the time after which the GSM Mod
-
ule should send a periodic SMS containing credit balance
information (if supported by your telephone operator).
Ø
Days: valid entries, 0 to 365.
Ø
Hours: valid entries, 0 to 23.
n
App/BOSS Cellular Communication
This subgroup is for setting the GPRS connection for
managing the control panel via the ABSOLUTA App
and for Teleservice via BOSS.
App/BOSS APN Enter the APN (Access Point Name)
supplied by the operator that provides the GPRS service.
Default: None.
+
Enter the correct APN for WAP/GPRS services or
some features may be limited (for more information,
please contact the operator of the service center).
+
The App/BOSS APN is the same as the Main Re
-
ceiver APN.
App/BOSS Username If required, enter the Username
supplied by the operator that provides the GPRS service.
Default: None.
+
App/BOSS Username is the same as the Main
Receiver User Name.
App/BOSS Password If required, enter the Password
supplied by the operator that provides the GPRS service.
Default: None.
+
App/BOSS Password is the same as the Main
Receiver Password.
n
Cellular
This subgroup is for setting the GPRS connection for
telemonitoring with Sur-Gard SYSTEM I / II / III receivers.
3
In order to comply with EN50131 Grade 3 standards,
ONLY use the ABS-IP IP Module to report alarms: the
ABS-GSM GSM/GPRS Module CANNOT be used.
+
Bearing in mind the delays which may occur in trans
-
mission via GPRS, which are caused by the activities
of the network manager, we recommend you pro
-
gram as many call attempts as possible, and that you
also provide a backup telephone number which
transmits alarms via GSM as well as via GPRS.
+
If you intend to use only one receiver, the primary
receiver options must be programmed.
DNIS Enter the DNIS number (Dialed Number Identifi-
cation Service), if required.
Default: None.
Fibro Account # Enter the Customer Code for the
Fibro
13
protocol: ask the Central Station.
Default: 0000FFFFFF.
+
Ensure a different Customer Code is assigned to
each Control Panel that transmits events to the
same receiver.
Receiver Functionality Mode Select the operating
mode of the receivers:
Ø
Primary and Backup, the Backup Receiver will only
be used when communication fails on the Main re
-
ceiver;
Ø
Redundant, events will be sent to the Main and
Backup Receiver at the same time.
Default: Primary and Backup.
+
If Redundant is selected, the APN 2, APN 2
Username and APN Password CANNOT modi
-
fied and are copied by the Main Receiver APN, the
Main Receiver User Name and the Main Re
-
ceiver Password respectively.
ABSOLUTA PROGRAMMING FROM THE PC 79
13 To transmit events to IP receivers, the Contact ID and SIA protocols are encapsulated in the Fibro protocol and this
protocol requires its own Customer Code to identify the system transmitting the events.