3
The Super User is available ONLY on Grade 3
Control Panels and must be enabled by a Master
User, as described in the USER MANUAL.
+
The Partitions disarmed with a Patrol PIN are auto
-
matically re-armed after the Partition Time-Patrol
(see Partitions Options Group).
A
In order to comply with the EN50131-1 and
EN50131-3 standards, the PIN n. 1’s User Type
must be Master.
+
Only Master PINs can arm/disarm the panel
through Status page. Normal, Limited and Patrol
PINs CANNOT arm/disarm the panel through Sta
-
tus page.
User Timer If this option is enabled, the Code will be
able to perform its programmed functions ONLY during
its Timer slots (see Timers options group).
Partitions If disabled, the PIN can NOT manage the
partition.
If ENABLED, the PIN can manage the partition.
Default: ONLY partition n. 1 enabled.
Arming Mode A This option will allow you to set the A
Mode Arming of the Partition:
Ø Away, Partition will Arm in Away mode;
Ø Stay, Partition will Arm in Stay mode;
Ø Instant Stay, Partition will Arm in Stay mode with
zero delay (Instant);
Ø Disarm, Partition will Disarm;
Ø No Action, the Partition does NOT change its state.
Default: stay arming of partition 1.
Arming Mode B As for Mode A but for B Mode Arm
commands at a Keypad.
Default: zero delay stay arming of partition 1.
Arming Mode C As for Mode A but for C Mode Arm
commands at a Keypad.
Default: no action.
Arming Mode D As for Mode A but for D Mode Arm
commands at a Keypad.
Default: no action.
Codes and Keys: Keys
This Option group is to setup the Digital Keys as follow.
Key Label This option is to enter a significant descrip
-
tion for the key.
Key Enabled If this option is enabled the key can con
-
trol the system.
If this option is disabled the key cannot control the sys
-
tem, however, it can still be programmed by a Master
PIN.
Master PINs can toggle the Enabled status of the keys
(also via the User Menu).
Key Arm Only If this option is enabled, the Key will be
able to Arm its Partitions ONLY.
Disarm Only If this option is enabled, the key will
ONLY disarm the partitions on which is enabled.
Silence Output If this option is ENABLED, the Key
may silence Outputs (Stop Alarms).
When the Key is brought close to a Reader:
Ø
if there are Outputs active due to alarm or tamper,
they will be silenced (forced to standby mode);
Ø
if the control panel is already in Silence mode, the Si
-
lence will be removed.
Silencing is signalled by the Reader’s green and red in-
dicators lights blinking quickly.
+
If this option is ENABLED, all the other options are
are blocked and disabled, and the Disarm Only
option is disabled, that is, a Key enabled for Silenc-
ing cannot perform other operations or vice versa.
+
If option EN50131 on the Reader is enabled, Outputs
reactivate themselves for a new alarm or tamper.
+
Silencing has NO effect on calls.
Key Patrol If this option is enabled, the Key will be able
to Disarm and Re-arm its Partitions during the pro
-
grammed Patrol Time. If a Partition is disarmed by a
Key with the Patrol option enabled, the Partition will
Re-arm automatically when the programmed Patrol
time of the Partition concerned expires.
Key Clear Panel Calls If this option is enabled, the
Control Panel will clear the running call and all the
queued calls — triggered by events associated with the
Control panel — when the key is recognized.
Key Clear Calls on Partitions If this option is en
-
abled, the Control Panel will clear the running call and
all the queued calls — triggered by events associated
with the Key Partitions — when the key is recognized.