The User option group is to setup the User PINs as follow.
Label This option (maximum 16 characters) is to iden
-
tify the User PIN in all the operations it is involved in
(e.g. User’s Name).
User Code If the PIN Transfer option is disabled, the
masked PIN (a series of dots) appears.
If the option PIN Transfer is ENABLED, the PIN is dis
-
played clearly: type the desired PIN or press the but
-
ton to have the BOSS generate a random one; enter all
“A” to disable the PIN.
Available If this option is enabled, the PIN can be pro
-
grammed and used for system access.
Many applications require fewer PINs. This option will
allow you to enable only the required number of PINs,
thus simplifying the programming process while in
-
creasing the security level. PINs which have not been
made Available can be considered inexistent.
Active If enabled, the PIN can perform the operations
for which it was programmed.
If disabled the PIN CANNOT access the system.
Default: ONLY enabled for PIN no. 1.
+
This option is read-only. ONLY a Master User PIN
can change the status of this option (see “TOUCH
KEYPAD OPERATIONS > (User) Menu > PIN”,
“LCD KEYPAD OPERATIONS > PIN Programming
(2.5)”, “TELEPHONE OPERATIONS > Disable Cur-
rent User PIN (
9) ”And “SMS OPERATIONS > Dis-
abling a PIN” in the USER MANUAL.
Keypad If this option is enabled the User PIN can man-
age the system by keypad.
Hold-up If this option is enabled, any Telephone ac-
tions (calls or reports) associated with the Valid PIN
event (generated by the PIN concerned) will not be sig
-
nalled on the LCD keypad ( will not appear over the i
icon).
DTMF If this option is enabled the User PIN can man
-
age the system by touchtone telephone.
Default: enabled for PINs from No. 2 to No. 10.
+
This option is NOT available for PIN N. 1.
SMS If ENABLED, the PIN can control some events by
SMS (see “Events and Actions > Remote Command
Events”) and can Arm/Disarm the Partitions via SMS
(Grade 2 Control Panels ONLY).
Default: enabled for PINs from No. 2 to No. 10.
+
This option is NOT available for PIN N. 1.
In And Group If this option is ENABLED, the PIN may
be used to disable Partitions with the option AND
Keys/Codes-Num set to 2 Keys and/or Codes or
3 Keys and/or Codes (see Partitions option group).
Default: enabled.
User type This option is required for setting the opera
-
tions that the User PIN can manage, as shown in Table 18.
74 Expandable Hybrid Control Panel
Operations
Super
Master
Normal
Limited
Patrol
Global Arming Yes Yes Yes Yes Yes
Special Arming Yes Yes Yes Yes NO
Disarming Yes Yes Yes Yes Yes
Alarm View Yes Yes Yes Yes Yes
Alarm Reset Yes Yes Yes Yes NO
Tamper View Yes Yes Yes Yes Yes
Tamper Reset Yes Yes*Yes*Yes* NO
Fault View Yes Yes Yes Yes Yes
Fault Reset Yes Yes*Yes*Yes* NO
Bypass View Yes Yes Yes Yes Yes
Partition Status View Yes Yes Yes Yes Yes
System Status View Yes Yes Yes Yes Yes
Overtime Request Yes Yes Yes NO NO
Phone Call Cancellation Yes Yes Yes Yes NO
Remote Service Request Yes Yes NO NO NO
Alarm Test Yes Yes Yes NO NO
Output Activation Yes Yes SI NO NO
Individual Partition Arming Yes Yes NO NO NO
Zone Test Yes Yes NO NO NO
En./Disab. Answer Machine Yes Yes NO NO NO
En./Disab. Installer Yes Yes NO NO NO
En./Disab. Automatic Arming Yes Yes NO NO NO
Date/Time Setting Yes Yes NO NO NO
En./Disab. PIN Yes Yes NO NO NO
Phone Number Programming Yes Yes NO NO NO
Personal PIN Change Yes Yes Yes NO NO
Zone Bypass Yes Yes NO NO NO
En./Disab. Super User** NO Yes NO NO NO
Key Disable Yes Yes NO NO NO
Log View Yes Yes Yes Yes NO
Zone Status View Yes Yes Yes Yes NO
GSM Module Status View Yes Yes Yes NO NO
SMS View Yes Yes Yes NO NO
IP Module Status View Yes Yes Yes NO NO
ABSOLUTA info View Yes Yes NO NO NO
Table 18 Operation available to various types of user:
*) operation NOT permitted with the Grade 3 Control Panels;