Management
r
127+1 Programmable Codes (from 4 to 6 digits).
r
Supports a total of 250 SAT Keys and/or Proxy-Cards.
r
Programmable Automatic Arming/Disarming features.
r
Partition Bypass for Patrol purposes with automatic
or manual re-arming.
r
5 Partitions Arming Mode:
– Away arming;
– A, B, C, D modes (each mode can be programmed
for any action on partitions).
(Only A and B modes are available for key-readers)
r
Programming from a LCD or Touchscreen keypad.
r
Local programming from a PC via RS232/USB.
r
Local/remote downloading/programming.
r
Accepts commands from touch-tone phones (Arm,
Disarm, Turn ON/OFF Outputs, Partition and Zone
status check).
r
Remote Talk/Listen-in (requires optional AS100
2-way audio station).
r
Remote Telephone Access via DIALLER or
ANSWER.
r
2000 event memory with date and time details.
r
Priority management of events (processing and re
-
porting): 1) Alarm/Hold-up, 2) Tamper, 3) Trouble
and Bypass.
r
3 function keys for immediate Alarm calls from Keypad.
GSM/GPRS Only with the optional ABS-GSM Module.
r Quad Band.
r Support for the GSM/GPRS channel.
r Main or backup dialler.
r Transmission of voice messages by GSM.
r Transmission of Contact ID and SIA by GSM.
r Transmission of events in Contact ID and SIA format
via GPRS to Sur-Gard SYSTEM II/III receivers.
r Reporting of events by SMS.
r Library of 250 SMS messages: 1 heading message,
8 status messages, and 241 personal messages.
r
32 events controlled by SMS.
r
32 events controlled by caller ID (at no cost).
r
Checks the control panel’s status by SMS.
r
Arm/Disarm Partitions via SMS (ONLY Grade 2 Con
-
trol Panels)
r
Checks the credit left on the prepaid SIM card.
r
Teleservice by Internet (GPRS).
IP Only with optional ABS-IP module.
r
Ethernet interface.
r
Transmission of Contact ID and SIA events to IP re
-
ceivers using FIBRO Protocol to Sur-Gard SYSTEM
I, II and III IP receivers.
r
Programming and monitoring of the ABSOLUTA
control panel on the LAN using BOSS.
r
Programming and monitoring of the ABSOLUTA
control panel via the internet, using BOSS.
r
Management of the ABSOLUTA control panel via the
internet, using the ABSOLUTA app.
r
Event notification via e-mail and on the ABSOLUTA
app (push notifications).
r
Interface for ABSOLUTA integration with third-party
software.
Power supply Deep discharge battery protection.
Housing
r
metal box for 17 Ah battery, with BAW35T12, BAW50T12
or BAW75T12 power supply and 2 M-IN/OUT.
r
plastic box for 7 Ah battery, with BAQ15T12, BAW35T12
or BAW50T12 power supply and 1 M-IN/OUT.
n
ABSOLUTA 16 features
r
Up to 8 Keypads.
r
Up to 16 Key Readers.
r
Up to 32 Input Expanders (on the M-IN/OUT modules
and/or PREMIUM and/or ABSOLUTA T-Line Keypads).
r
Up to 16 Output Expanders (on the M-IN/OUT modules).
r
Up to 16 fully-programmable wired zones.
r
Up to 6 Outputs.
r
Up to 32 wireless zones (with external receiver).
r
Up to 32 total zones (wired + wireless).
r
Up to 8 independent Partitions.
n
ABSOLUTA 42 features
r
Up to 8 Keypads.
r
Up to 32 Key Readers.
r
Up to 32 Input Expanders (on the M-IN/OUT modules
and/or PREMIUM and/or ABSOLUTA T-Line Keypads).
r
Up to 16 Output Expanders (on the M-IN/OUT modules).
r
Up to 42 fully-programmable wired zones (with exter
-
nal Input Expanders).
r
Up to 20 Outputs (with external Output Expanders).
r
Up to 32 wireless zones (with external receiver).
r Up to 42 combined zones (wired + wireless).
r Up to 8 independent Partitions.
n ABSOLUTA 104 features
r Up to 16 Keypads.
r Up to 32 Key Readers.
r Up to 32 Input Expanders (on the M-IN/OUT modules
and/or PREMIUM and/or ABSOLUTA T-Line Keypads).
r Up to 16 Output Expanders (on the M-IN/OUT modules).
r Up to 104 fully-programmable wired zones (with ex-
ternal Input Expanders).
r
Up to 50 Outputs (with external Output Expanders).
r
Up to 4 power Supply Stations.
r
Up to 32 wireless zones (with external receiver).
r
Up to 104 combined zones (wired + wireless).
r
Up 16 independent Partitions.
ABSOLUTA INTRODUCTION 7
Versions
Main
Boards
Boxes
Power
Supplies
ABS16P15*
ABS16
ABS-P
BAQ15T12
ABS16P35* BAW35T12
ABS42P15*
ABS42
BAQ15T12
ABS42P35* BAW35T12
ABS42P50
* BAW50T12
ABS104P50
* ABS104 BAW50T12
ABS16M35
ABS16
ABS-M
BAW35T12
ABS16M50-G3
** BAW50T12
ABS42M50*
ABS42
BAW50T12
ABS42M75* BAW75T12
ABS104M50*
ABS104
BAW50T12
ABS104M75* BAW75T12
ABS104M75-G3
** BAW75T12
Table 2 *) Certified Grade 2 Control Panels;
**) Certified Grade 3 Control Panels.