View Bypass The keypad shows the Bypass if pres
-
ent:
BYPASS! 001/003
Zone 001
Ø
the display top line shows the current bypass dis
-
played respect to the total of bypass, on the right;
Ø
the display bottom line shows the label of the by
-
passed zone.
16. Press ENTER to skip to “View Partition and System
status”.
Press A to view the next bypass: if there are no
more bypasses to view, the display shows the Parti
-
tion and System status.
View Partition and System status The display top
line shows the date and time.
The display bottom line shows the state of the first 8
Partitions, on the left, as follow.
Feb/04/11 14:32
DDDDDDDD
Ø
D: Disarmed.
Ø
A: Away Armed.
Ø S: Stay Armed.
Ø I: Instant Armed (Stay/Away with Zero Delay).
Ø –: Not assigned to the Keypad.
The following information on the right.
Icon
Signalled by
Description
S x
Control Panel Tamper (opened or wall re
-
moved)
T x
System Tamper (AS terminal)
b x
Peripheral Tamper (Keypad, Key Reader, Ex
-
pander IN/OUT, Power Station, Wireless Re
-
ceiver)
f x
False Key
s x
Peripheral Lost (Keypad, Key Reader, Ex
-
pander IN/OUT, Power Station, Wireless Re
-
ceiver)
t *
Installer Access enabled (locally and re
-
motely)
r *
Answerphone facility enabled
i
Telephone Line busy
17. Press ENTER to view the Option Menu.
INSTALLER
1act. 2prg 3view
18. Select the required option then go to the relative
paragraph: you can either select the required op
-
tion group by pressing the relative key then scroll to
the required option by pressing the key a and b,or
you can directly go to the required option by enter
its address as indicated following.
r
1: actions
Ø
1.1: Zone Test
Ø
1.2: Output Test
Ø
1.3: Changing the PIN
Ø
1.4: Firmware Upgrade by an USB key
Ø
1.5: Logger Downloading on a USB key
Ø
1.6: Modify the LCD Keypad language
Ø
1.7: Enabling Level 4 access
Ø
1.8: Clear Faults and Tampers
Ø
1.9: Option Programming by Keypad
r
2: programming
Ø
2.1: Voice Message Recording
Ø
2.2: BPI Device enrolling
Ø
2.3: Wireless Device enrolling
Ø
2.4: Key (card/tag) enrolling
Ø
2.5: Message Download/Upload via USB Key
Ø
2.6: Option Download/Upload via USB Key
Ø
2.7: Factory Default
Ø
2.8: Telephone Communicator
Ø
2.9: Key Disabling/Enabling
r 3: view
Ø 3.1: View Logger
Ø 3.2: View the Firmware Version
Ø 3.3: View Zone Status and Zone Bypassing
Ø 3.4: View GSM Module Status
Ø 3.5: View IP Module Status.
Quit from the Operations
Press ESC until the display shows the following mes
-
sage (if you are on the Installer Level):
INSTALLER
Exit ?
or the following message (if you are on the Level 4):
LEVEL 4
Exit ?
Press ENTER to confirm.
+
The keypad quit from the operations even when
you do not press any key before the timeout ex
-
pires: you have 30 seconds timeout when the key
-
pad is displaying information about the system
(Alarms, Tampers, Faults, Bypass, Partitions and
Status) and 180 seconds when in the option
menu.
90 Expandable Hybrid Control Panel