ABSOLUTA PROGRAMMING FROM THE PC 65
EVENTS OCCURS WHEN... ENDS WHEN...
False Key Event ... a false Key is used on the Reader. ... the false Key has been removed from the
Reader.
Valid Key ... the Key is used on a Reader. ... the Key is removed from the Reader.
Valid Key on Key
Reader
... a valid Key is used on the Reader. ... the Key is removed from the Reader.
Valid Code ... arming, special arming, disarming or ENTER
key is pressed after entry the User PIN.
SPOT EVENT!
Valid Code on
Keypad
... arming, special arming, disarming or
ENTER key is pressed after entry of a VALID
User PIN on the Keypad.
SPOT EVENT!
Invalid Code on
Keypad
... arming, special arming, disarming or
ENTER key is pressed after entry of an
INVALID User PIN on the Keypad.
SPOT EVENT!
Super Key 1 on
keypad
... the Key 1 on the LCD Keypad (the Key on
the Touch Keypad) is pressed e hold for 3 (2)
seconds.
SPOT EVENT!
Super Key 2 on
keypad
... the key 2 on the LCD Keypad (the Key on
the Touch Keypad) is pressed e hold for 3 (2)
seconds.
SPOT EVENT!
Super Key 3 on
keypad
... the key 3 on the LCD Keypad (the Key on
the Touch Keypad) is pressed e hold for 3 (2)
seconds.
SPOT EVENT!
Valid Keyfob ... a button on the valid keyfob has been pressed SPOT EVENT!
Super Key on
Keyfob
... the button ! of the Wireless key is pressed
and held down for 2 seconds.
SPOT EVENT!
Keyfob Low
Battery
... the battery of the keyfob is low. ... the battery is replaced.
Table 12 Key and PIN Events.
EVENTS OCCURS WHEN... ENDS WHEN...
General System
Alarm
... a Zone — regardless of its Type and Parti-
tion detects Alarm conditions.
... ALL events generated by the zones of all
Partitions restore to standby.
General System
Tamper
... a Zone — regardless of its Partition detects
Tamper conditions.
... ALL Tamper events generated by the zones
of all Partitions restore to standby.
Warning Low
Battery on
Wireless Detector
... the battery of at least one Wireless Detector
is low.
... the last Wireless Detector has closed and
ALL Wireless Sensor batteries are charged.
Tamper on Main
Unit
... the Control Panel Tamper switch opens. ... the Tamper switch restores.
Service Jumper ... the SERVICE jumper is inserted ... the SERVICE jumper is removed.
Tamper on
External Siren
... External Siren Tamper is set for the Panel
AS Tamper option AND the AS terminal is un
-
balanced.
… External Siren Tamper is set for the Panel
AS Tamper option AND the [AS] terminal is bal
-
anced (grounded with a 10,000 ohm resistor).
Fault on
External Siren
... the external siren fails. ... ALL the fault conditions on the external siren
restore.
Tamper on
Internal Siren
... the supervised output is tampered. ... the Output tamper event ends.
Fault on Internal
Siren
... the internal siren fails. ... ALL the fault conditions on the internal siren
restore.
Tamper BPI
Device
... a BPI Device Tamper switch or Wall-Tamper
switch open.
... all BPI Device Tamper switches and
Wall-Tamper switches restore.
Wireless
Receiver Tamper
... the Tamper switch or Wall-Tamper Switch of
a Wireless Device is tripped.
... the Tamper and Wall-Tamper switches of all
Wireless Devices are closed.
Warning BPI
peripheral
... an enrolled BPI peripheral does not respond
to the Control Panel.
... ALL the BPI peripherals respond to the Con
-
trol Panel.
WLS Receiver
Lost
... an enrolled Wireless Device does not re
-
spond to the Control Panel.
... ALL the enrolled Wireless Devices respond
to the Control Panel.
Table 13 System Events (continued on next page).