EasyManua.ls Logo

Bentel Security ABSOLUTA 16 - Page 49

Bentel Security ABSOLUTA 16
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Time-Negligence Under normal circumstances, Us
-
ers Arm their systems with a certain regularity, if this
does not occur, it may be due to Negligence on the
User’s behalf or may mean that the User is in difficulty
(due to serious illness, accident or delinquency), in
which case, this feature will prompt the Central station
operator to take the necessary action.
This option will allow you to set the Negligence Time.If
the system is not Armed within the programmed time,
the Control Panel will generate the Negligence on Par
-
tition event.
Ø
Valid entries: 0 through 40 days in 1-day steps.
Ø
If this option is left at default (0), Negligence will not
be signalled.
Negligence will be signalled by:
Ø
the Event negligence on partition event — relevant
to the Partitions the Zone is assigned to.
Time-Inactivity This option allows the system to moni
-
tor Alarm Zone inactivity (non-detection of motion),
when the Partition is Disarmed. The Inactivity function
provides protection against the detector blinding and al
-
lows the system to detect zone malfunction. Under nor
-
mal circumstances, users disarm the system when they
are on the premises, therefore, the zones should detect
motion (violation) quite frequently. If this does not occur,
the system will suppose that the user is unable to move
(due to serious illness, accident or delinquency) and as
a result will generate a Delinquency on Partition
event, thus prompting the Central station operator to
take the necessary action.
Ø Valid entries are 0 through 240 hours (10 days)
1-hour steps.
Ø Zero meas that Zone Inactivity will not be signalled.
Ø The default setting is Zero.
Zone Inactivity will be signalled by:
Ø
the event Delinquency on partition — relating to
the Partitions the Zone is assigned to.
+
The G LED (ON) signals several different types of
Trouble events. If the signal is due to Inactivity, the
Keypad (in View Trouble Mode) will show the In
-
activity message (refer to “View Trouble
Mode” in the USER’S MANUAL).
The following information will be recorded in the Event log:
Ø
TYPE: Inactivity
Ø
ID. EVENT: Description of the Partitions the Zone is
assigned to;
Ø
AGENT: None;
Ø
ID. AGENT: Description of the Zone that triggered
the Inactivity event.
Zone Inactivity will end when:
Ø
the Zone restores standby;
Ø
the Zone triggers an Alarm;
Ø
ALL the Partitions the Zone belongs to Disarm.
The end of a Zone Inactivity event will be signalled on
the G LED (OFF) on Keypads which are enabled on at least
one of the Partitions the Zone belongs to.
+
The G LED switch OFF ONLY when there are no
Inactive Zone or Trouble signals relating to the
Keypad Partitions.
As the event is a Spot event, the termination of a
Zone Inactivity event will not be signalled.
Time-Patrol This option will allow you to set the Patrol
Time. If the partition is disarmed by a User Code or a
key with the Patrol attribute (refer to “PIN and Key”), it
will rearm automatically when the programmed Patrol
Time expires.
Valid entries: 0 through 254 minutes in 1-minute steps.
Default setting: 10 minutes.
And Keys Code-Time After arming a partition, the AND
Codes Timeout is not running. After entering an AND
code or inserting an AND key while the timeout is not run
-
ning the AND Codes Timeout starts. Before this timeout
expires, the number of keys and/or codes set in the option
And Keys Codes Num must be entered/inserted, and
then the last AND code or key used is allowed to disarm
the partition itself. If the timeout expires without the com
-
plete codes/keys group is used an event is stored in the
system logger. The timeout is enabled to restart any time
the partition is re-armed or after it expires.
And Keys Codes-Num Set the number of And
Keys/Codes required to disarm the partitions.
You can set Disabled, (an Key/Code ONLY is neces-
sary) 2 or 3.
If you set 0 the option is disabled: you need to use only
one key/code to disarm the partitions even if you have
set And Keys/Codes.
Timer-Arm This option provides the system with an
Arm command filter. If a Timer window is associated
with a Partition, the system will carry out commands to
Arm the Partition concerned ONLY when the respective
Timer window is running (refer to “Scheduler - Timers”).
Timer-Disarm This option provides the system with a
Disarm command filter. If a Timer window is associated
with a Partition, the system will carry out commands to Dis
-
arm the Partition concerned ONLY when the respective
Timer window is running (refer to “Scheduler - Timers”).
Max. Overtime Requests This option will allow you to
set the maximum number of Overtime Requests.
EXAMPLE: If a Timer controlled Partition is scheduled
to Arm at 17:45 — and the Overtime request period is
set at 60 minutes, and the Max. No. of Overtime re
-
quests is set at 2 — Arming can be postponed until
19:45 by two Overtime requests (17:45 + 2 x 60 min
-
utes), after which, Overtime requests will be ignored.
The maximum Overtime request is 180 minutes.
+
Overtime Requests will affect the imminent Arming
event ONLY.
ABSOLUTA PROGRAMMING FROM THE PC 49

Table of Contents