OPERON D 850 SURGICAL TABLE
SPECIAL SAFETY INSTRUCTIONS
Rev. 1 700000120
S-9
PATIENT POSITIONING
WARNING
WARNING — POSSIBILITY OF
TIPPING: Table stability may be
compromised if patients are
positioned beyond the following
limits:
The patient's pelvis should not be
extended beyond the end of the seat
section. The patient’s legs may be
placed on a leg extension attached to
the end of the leg section.
WARNING
WARNING — POSSIBILITY OF
TIPPING: If FULL SLIDE
FORWARD IS REQUIRED, the
patient’s pelvis must always be
located over the seat section when in
normal orientation. Utilizing full
forward slide while the patient’s
pelvis is on the leg section can
impair table stability and result in
patient injury or equipment damage.
WARNING
WARNING — The leg section may
be removed from the table. If it is
left on the table, use caution when
raising the leg section while the
patient is in the normal perineal
position.
WARNING
WARNING — The back section may
be removed from the table.
Full articulation and full slide in either
direction can be safely achieved with a 1000lb
(453g) patient if these steps are followed.
OPERATION
WARNING
WARNING— The table should
always be locked to the floor
whenever a patient is on the table or
being transferred to or from the
table. This is accomplished by
extending the table’s feet by
activating the FLOOR LOCK
function. This table is not intended
for patient transport.
WARNING
WARNING Weight Limit in
reverse, while not recommended, it
is possible to place a patient in
reverse orientation. Patient weight
must not exceed 500 lbs. when
placed in reverse.
CAUTION
CAUTION — Storage of clamps,
accessories, etc., on the base cover
may result in damage to lift column
shields and prevent proper elevation
or descent of the table.
TABLE MOVEMENT WITH PATIENT
WARNING
WARNING — If the table needs to
be moved with a patient on the
table, it is very important to follow
the following instructions to prevent
patient injury or equipment damage.
WARNING
WARNING — The table should not
be used to transport a patient over a
long distance. This procedure is
only meant for repositioning the
table in the surgical suite.
PRIMARY HAND PENDANT
FUNCTIONS
AUXILIARY HAND PENDANT
WARNING
WARNING — The auxiliary hand
pendant functions will operate
regardless of whether the floor feet
are locked or unlocked. If the floor
feet are unlocked, the table may roll
when the manual pump is operated.
CAUTION
CAUTION — The auxiliary hand
pendant does not have the following
functions: FLEX, REFLEX, CHAIR,
RETURN TO LEVEL, UROLOGY,
or SLIDE. This pendant is intended
to be used for completing
procedures, followed by charging
the batteries or servicing the table.
WARNING
WARNING — When using the
auxiliary pendant, the software
controlled limits are not active.
DAMAGE MAY OCCUR. Review
the user controlled limits section of
this manual.
HEADREST
WARNING
WARNING — Do not mount knee
crutches or leg holders to the
headrest side rail. The headrest
should only be used for supporting
the head or feet. Do not lean on the
headrest. The headrest has a weight
limit of 50 lbs.