Switch on all consumers individually, and check the correct function and
movements according to the operating signs.
►
Run through the hydraulic functions several times, starting at a slow
speed. Check the hydraulic system for leaks when doing so.
►
Move to the limit positions of all hydraulic cylinders once. Then stop
the hydraulic cylinders at intermediate points and make sure that the
hydraulic cylinders come to a stop immediately and maintain their
position.
►
For information about performing the function test/initial startup of the
optional accessory and equipment according to the information of the
respective manufacturer, see the relative third-party documentation
(→ part 3 of the documentation).
►
Switch off the machine (→ 8.10).
7.3.3 Checks after initial startup/function test
WARNING! Risk of burn injuries!
It is possible to receive serious burn injuries due to very hot machine
parts.
n Always wear personal protective equipment.
n Always allow the machine to cool down before carrying out
repairs or maintenance work.
50-020-1011-900_EN
1.0 - © 2/15/2017
157
7 Installation, initial startup and function test
7.3 Initial startup and function test of the machine