540
HYDRAULIC SYSTEMS
Studio ti 03312 540-04usa
206
9
The controls of the black water tank are located on the main electric panel
in the salon.
1. Full tank alarm warning light. The toilet pumps are disconnected and
cannot be used
2. Pre-alarm warning light for black water level. Only a limited number
of operations is available
3. Buzzer. Sounds when the tank is full
4. It clears off the buzzer
5. System test
There are two ways to empty the holding tank:
dockside pump-out using the WASTE drain fitting (within Territorial
waters);
onboard holding tank pump (outside Territorial waters).
To accomplish onboard holding tank pump-out:
switch on the holding tank pump differential circuit breaker;
open the intake seacock for overboard drain;
under the forward companionway sole, you will find the momentary
switch for the pump. Depress the momentary switch, and hold it until
you hear a change in the sound from the pump, indicating that the
tank is empty.
NOTICES
After draining the holding tank overboard, close the sea valve serving
the tank discharge thru-hull to prevent seawater from coming back into
the tank.
j
WARNING
For all pleasure yachts it is prohibited to drain at sea the on board toilets
inside of harbors, landings and moorings dedicated to craft’s anchor
riding, and also within the limit of beaches visited by swimmers, as
stated in the single decree of the Port Authorities.