540
15
TROUBLESHOOTING
Studio ti 03312 540-04usa
345
15.13 AIR-CONDITIONING UNIT
For further information, please refer to BERTRAM Customer Support.
Problem Cause Action
1. Display does not operate −−Turn circuit breaker on
Check CX/CXP cable and connections
Replace keypad/display
Replace power logic board
2. Erratic temperature display −−Perform a factory memory reset
Check temperature sensor, cable and
connection
Ensure the temperature sensor is installed
properly
Calibrate temperature
Replace power logic board
3. Erratic system operation −−Perform a factory memory reset
Check CX/CXP cable and connections
Check temperature sensor, cable and
connection
Replace keypad/display
Replace power logic board
4. The unit will not operate at all Blown fuse or tripped circuit breaker
Low voltage to unit
Replace fuse with time delay type or reset
breaker. Check for correct sizing
Check shore power supply and rating of
electrical power cord to boat

Table of Contents