TROUBLESHOOTING
Studio ti 03312 540-04usa
346
15
5. Air from the unit does not feel cool in the
“Cool” Mode or warm in the “Heat” Mode
− The selector switch is set for “Fan only”
− The thermostat is set incorrectly
− Water flow is restricted
− Switch the system into the “Cool” or “Heating”
mode
− Set the thermostat for a cooler or warmer
setting
− Clear restriction
6. The unit operates but the stateroom fails to
cool normally
− Dirty air filter
− The thermostat is set too high
− Clean lint screen or air filter
− Reset the thermostat to a cooler setting
7. Compressor cycle on and off − Dirty air filter
− Water flow restriction
− Clean lint screen or air filter
− Clear restriction
8. Water leaks in stateroom − Condensate drain is clogged
− Blockage in hose
− Clean out drain holes
− Clean hose. Check downhill routing of hose
Problem Cause Action