15.7 BILGE PUMP
For further information, please refer to BERTRAM Customer Support.
Problem Cause Action
1. The pump does not start No voltage
Blocked impeller
Electric section defective
Check the value of the line voltage
Clean the impeller and the pump casing
Consult BERTRAM Customer Support
2. The pump runs but it does not work Dirty valve and filter
Over suction depth
Air in suction
Clean valve and filter
Install the pump closer to the water static
level
Check the seal of the suction pipe
Fill the pump casing of liquid
With DC and three-phased motors invert the
polarities
3. The pump vibrates and is noisy The pump has not been primed at first start
Wrong rotation direction
Increase or decrease the capacity
Vent air from the system
4. The operation of one pump is irregular Damaged impeller and blower
Pressure required from the system higher
than that-one the pump can supply
Check the internal air pressure in the
membrane
Check/Have it cleaned