EasyManua.ls Logo

Beumer stretch hood S - User Manual

Default Icon
192 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
BEUMER stretch hood® S
BA-6090103-EN
19.08.09
1
Operating instructions
Machine type
BEUMER stretch hood
®
S
Machine no.
6090103.10 - 210
Project
BECTON DICKINSON
Document no.
BA-6090103-EN

Table of Contents

Questions and Answers

  • R
    Robert HicksAug 25, 2025
    What to do if the film has torn on Beumer Industrial Equipment?
    • J
      joshua54Aug 26, 2025
      If the Beumer Industrial Equipment film has torn during the stretching process, activate the "Starting position" function. Remove the torn film and then repeat the stretching process.
  • K
    Karen RamirezAug 26, 2025
    What to do if the safety photocell (SLS) has been tripped on Beumer Industrial Equipment?
    • M
      Manuel RushAug 27, 2025
      If the Beumer Industrial Equipment safety photocell (SLS) has been tripped, activate the reset key on the evaluator, ensuring that no one is within the safety area. If the safety photocell is out of function, readjust the safety photocell, check the wiring, and then activate the reset key on the evaluator.
  • E
    Eric HarrisAug 27, 2025
    Why is no film hood being drawn over the package in Beumer stretch hood S Industrial Equipment?
    • Z
      Zachary DixonAug 27, 2025
      If the Beumer Industrial Equipment is not drawing a film hood over the package, it may be because the "without stretching" option has been selected for the pallet transport system. Switch to "with film" in the "Programme preselection" window or deselect the "without stretching" option in the "Preselection" window.
  • Y
    Yvette KimAug 27, 2025
    What to do if the package is not in position on Beumer Industrial Equipment?
    • A
      agreeneAug 27, 2025
      If the Beumer Industrial Equipment package is not in position, manually center the package under the stretch hood. Ensure the photocells on the conveyor, which are used to check the pallet's position, are activated.
  • R
    Rachel GonzalezAug 28, 2025
    What to do if the maintenance platform is not in position in Beumer Industrial Equipment?
    • B
      Brittany SnyderAug 28, 2025
      If the Beumer Industrial Equipment maintenance platform is not in position, push the maintenance platform into the correct position and check the operating distance and function of the proximity switch. If the position of the maintenance platform is not detected, check the proximity switch and the wiring.
  • C
    Courtney BrownAug 29, 2025
    How to exit repair mode on Beumer stretch hood S?
    • V
      Victoria DorseyAug 29, 2025
      If the Beumer Industrial Equipment is in repair mode, deselect the repair mode. If the dummy plug has not been plugged in, insert the dummy plug in its intended place.
  • J
    Jessica KnappAug 30, 2025
    How to set the local mode selector switch to automatic on Beumer stretch hood S?
    • Z
      zoe79Aug 30, 2025
      If the local mode selector switch for the drive motor on the Beumer Industrial Equipment is not in the Automatic position, set the local mode selector switch to Automatic.
  • H
    hernandezcharlesAug 23, 2025
    What to do if the Beumer Industrial Equipment emergency stop is activated?
    • W
      Warren GibbsAug 23, 2025
      If the Beumer Industrial Equipment emergency stop is activated, first identify which emergency stop switch has been triggered. Then, resolve the underlying issue that caused the activation. If the key-operated switch of the safety doors has been switched off, switch it on again. If the maintenance switch has been switched off, switch it on again. If the emergency stop relay in the control cabinet has been switched off, press the "Reset emergency stop" key.
  • D
    David OconnellSep 1, 2025
    What to do if the PB address or DP slave have failed on Beumer Industrial Equipment?
    • A
      Amy MosleySep 1, 2025
      If there is no connection to the client of the Profibus on the Beumer Industrial Equipment, check the wiring, function, and addressing of the client. Also, verify the settings using the circuit diagram.
  • R
    Robert SullivanSep 1, 2025
    What causes a muting error of the safety photocell on Beumer Industrial Equipment?
    • T
      Theresa ThomasSep 2, 2025
      If the Beumer Industrial Equipment safety photocell was disabled for more than 10 minutes, remove any foreign objects from the safety area. Check and adjust the disabling photocells.

Summary

Intended Use and Safety Zones

Technical Data and Site Requirements

Installation Site Requirements

Specifies conditions for building, foundation, and lighting at the installation site.

Power Supply Specifications

Details electrical energy requirements for the system's operation.

Pneumatic Energy and Material Handling

Film Specification and Performance Data

Technical Description of System

Description of System Modules

Hood Applicator Head Details

Hoist and Stretch Frame Assembly

Crimping and Stretching Unit Function

Safety Guidelines and Devices

General Safety Instructions

Classifies safety instructions into three hazard levels (Danger, Warning, Caution).

Safety Devices and Structures

Explains the role of guards and protective structures for safety.

Installation Safety and Procedures

Installation Safety Instructions

Emphasizes informing personnel and controlling access during installation.

Lifting Equipment Safety

Warns about hazards associated with improperly fastened loads.

Installation Preparation and Tools

Installation Sequence and Procedures

Installation Check Procedures

Checking Screw and Bolt Connections

Details how to check screw and bolt connections for proper fit and tightness.

Commissioning Safety and Initial Start-up

Commissioning Safety Instructions

Emphasizes operation by trained personnel and warns against unauthorized use.

Initial Start-up Requirements

Lists essential checks before the first start-up of the machine.

Power Supply and Pneumatic Setup

Switching on Electrical Power

Guides on how to activate the main power supply via the control cabinet.

Pneumatic Energy Connection

Details connecting the compressed-air system and setting operating pressure.

Operation Safety Guidelines

Emergency Stop System Functionality

General Operation and System Control

General Operational Information

Covers operator responsibilities, malfunction handling, and personnel training.

Switching Machine On and Off

Provides step-by-step instructions for starting and stopping the machine.

Safety Photocell and Muting Device

Control Unit for Safety Photocell

Explains the control unit's function for safety photocells and muting.

Restart and Reset Procedures

Safety Photocell CPSET M13 Operation

Control Unit for CPSET M13

Describes the control unit's role in the CPSET M13 safety photocell system.

Control Cabinet and Elements

Control Cabinet Components Overview

Lists and explains the function of control cabinet elements and displays.

System Visualisation and Interface

Visual Display System Functions

Operator Panel Function Keys

Parameter Input Methods

Inputting Parameters via Keyboard

Password Protection and Access Levels

Entering Passwords and System Settings

Password Management and User Logout

System Operation and Basic Screen

Preset Functionality and Setup

Numerical Preselection and Modes of Operation

Functional Areas and Operation Modes

Starting Position and Pallet Interruption

Film Insertion Process

Parameter Management

How to Select Parameters

Explains how to enter and modify parameters for operating and service personnel.

Operating Personnel Parameters

Service Personnel Parameters

Service Personnel Parameter Details

Service Personnel Parameter Details (Cont.)

Error Message Handling

Fault Message Display and Buffer

Fault Buffer Reset and System Messages

Trouble Shooting Safety and Malfunctions

Trouble Shooting Safety Instructions

Emphasizes safety precautions before starting maintenance and work on electrical systems.

Malfunction Identification

Lists information required by after-sales service for prompt assistance with malfunctions.

Troubleshooting Common Issues

Pre-Start-up Troubleshooting

Provides solutions for issues encountered before the initial machine start-up.

Troubleshooting Failures

Guides on resolving common failures related to safety and operational stops.

Troubleshooting Common Issues (Cont.)

Troubleshooting Safety Device Trips

Addresses issues with safety photocells, voltage, and air pressure.

Troubleshooting Component Issues

Covers problems with film roll drives, motors, sensors, and switches.

Troubleshooting System and Film Issues

Addresses pallet transport system disconnects and film draw problems.

Maintenance Safety and Electrical Checks

Maintenance Safety Instructions

Emphasizes safety precautions before starting maintenance work.

Electrical Equipment Maintenance

Details safety notes and regular checks for electrical equipment.

Inspection Schedule and Checks

Inspection List for Subassemblies

Provides a list of subassemblies and the work/checks to be performed at different intervals.

Inspection Schedule and Checks (Cont.)

Inspection of Pneumatic, Gear, and Sensor Systems

Continues the inspection list for pneumatic components, gears, and sensors.

Inspection of Chain Drives

Continues the inspection list for chain drives, including visual checks and lubricant status.

General Maintenance and Component Care

General Maintenance Instructions

Stresses the importance of regular maintenance for safe operation and cleaning.

Sealing Rail Maintenance Procedure

Lubrication Principles and Component Lubrication

Lubricating Chain Drives and Linear Guides

Lubricant Table and Specifications

De-commissioning Safety and Waste Disposal

Disposal of Machine Components

Transport Safety Instructions

Transport Instructions and Packaging Symbols

Beumer stretch hood S Specifications

General IconGeneral
BrandBeumer
Modelstretch hood S
CategoryIndustrial Equipment
LanguageEnglish