Installation
Instruction manual NSF VSI / VSI W / VSI T / VSI
TW
24 / 101 38065447002 en-US
After positioning remove handles.
Cover drill holes with the cover caps pro-
vided.
Fig.7: Handles, rear
4.2 Transport and storage
The machine has to be transported and stored in accordance with the symbols on the pack-
aging.
Before installation, store and transport the machine in the original packaging. We recommend
keeping the original packaging.
WARNING!Tipping hazard.
The machine with stand must only be moved on level surfaces with a very low degree of
roughness and unevenness of not more than 2 cm.
The machine must not be moved during operation.
Unplug power plug before moving the machine!
4.3 Installation and assembly
Installation, start-up, as well as instructions on how to operate, clean, maintain and service
the device are provided for the first time by the relevant Bizerba customer services.
Only lift machine out of its packaging by using the handles [}15]. Do not touch gauge plate,
carriage, support for weighing conveyor and conveyor belt in order to set up the machine.
CAUTION
Risk of crushing!
Carriage might move due to its unladen weight.
– Be careful when unpacking.
4.3.1 Installation requirements
Safe operation of the slicer within the standards and guidelines is ensured on the Bizerba
stand. Stand and slicer bear a CE mark (or UL/cUL mark within the area of application). The
integrated scale can only be reliably used with the Bizerba stand.