Maintenance
Instruction manual NSF VSI / VSI W / VSI T / VSI
TW
78 / 101 38065447002 en-US
The cleaning agent can be acquired from the BIZERBA customer services:
Designation Order no. Packaging unit
P3-steril 50003250000 5 liters
P3-riksan 50003270000 5 liters
P3-alcodes 50003260000 5 liters
H1-Service-Oil 94008900022 400 ml
8.5 Preparing the machine for operation
Attach the components as follows:
Deflector
CAUTION!Risk of injury on deflector
edge.
Move deflector downward up to mag-
netic lock while observing exact position-
ing in recess of blade guard ring.
Fig.89: Deflector
Blade cover
Hold blade cover at handle, tilt towards
blade and fix into position with the stud.
Fasten lock behind blade guard ring.
NOTICE!Do not mix up with covers of
other machines.
Fig.90: Blade cover