Instruction manual NSF VSI / VSI W / VSI T / VSI
TW Installation
38065447002 en-US 25 / 101
Alternatively the slicer can be installed on torsion-resistant furniture which is suitable for the
weight of the machine. In this case, the user is responsible for safe operation and reliable use
of the integrated scale.
The installation surface must be:
– large enough [}96]
– level and even (variation from horizontal max. 1 degree)
– slip-proof and tilt-proof
– stable and firm [}96]
Recommended table height is approx. 800 mm.
Make sure there is a safety distance of 100 mm between the machine (max. work area) and
the wall if machine is installed on a table, and of 500 mm if machine is installed on a stand.
4.3.2 Position on stand
Installation as well as instruction on how to operate the stand are initially provided by the
Bizerba service.
DANGER
Tipping hazard when improperly installed!
This may result in serious injuries and damage to property.
– Installation requirements must be met.
– Operate machine on stand only if its weight rests on the feet and the
casters are locked.
– The machine must only be moved on a level surface with a very low
degree of roughness and unevenness of not more than 2 cm.
– Installation, moving and operation are not permitted on surface that
are not level.