Instruction manual NSF VSI / VSI W / VSI T / VSI
TW Machine and operating elements
38065447002 en-US 39 / 101
The shingling distance is fixed.
In order to obtain the preset shingling dis-
tance, the shingling length is reduced or in-
creased.
If the anchor is set to shingling distance,
then the shingling length can not be
changed. The numeric input field and the
up-/ down keys are grayed out and disabled
for operator entry.
Fig.15: Anchor set to shingling distance
If the anchor is set to shingling length, it will be set back automatically for the shingling dis-
tance and vice versa.
If the number of slices required to reach the target weight does not fit the
depositing belt, the portion is discharged as Underweight.
5.2.3 Depositing patterns
Stacking
The sliced product is deposited on top of each other and forms one or more stacks.
The overall pattern may consist of several stacks and equals a portion. The depositing table
has room for only one portion.
Several parameters influence the look of the depositing pattern: