Instruction manual NSF VSI / VSI W / VSI T / VSI
TW Maintenance
38065447002 en-US 91 / 101
Installation points for seals and sealings between the following parts:
Gauge plate - machine housing
Carriage plate - handle
Conveyor belt - machine housing
Chain frame - machine housing
Depositing arm - machine housing
Spindle - carriage 2x
Product holder guide shaft - Product holder guidance 2x
Carriage plate - carriage mounting
Blade - machine housing
Blade guard - machine housing
Blade guard - machine housing 2x
Display and operating unit - machine housing
Drive housing - machine housing
Drive housing - motor tower
Carriage mounting - carriage foot
Seals and gaskets 1 to 15 used in food and splash water areas need to be checked.
The time distance between the checks must be less than 12 months.
The checks need to be done by the manufacturer or one of his service agents.
WARNING
Damaged or missing seals and sealings!
Damage to health, damage to objects.
ā In case of missing or damaged sealings the slicer must no longer be
operated until the damage is remedied.