EasyManua.ls Logo

BK Precision PVS10005

BK Precision PVS10005
126 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
83
[:NUMber] <NR1 | ?>
Set or return step number
:ACTion <OFF/0, ON/1,
NAC/2, END/3
| ?>
Set or return step n action state
:CURRent <NRf | ?>
Set or return step n current value
:ONTime <NRf | ?>
Set or return step n time value
:VOLTage <NRf | ?>
Set or return step n voltage value
:TOTAl?
Return program total n step numbers
PROTection
Protection subsystem
[:STATe] ?
Return the protected state, 0=no
protection happened, 1=OVP, 2=OCP,
3=OPP, 4=CV to CC and 5=CC to CV
:CCCV <Bool | ?>
Set or return CC to CV protection
switch
:CLEar
Reset latched protection
:CVCC <Bool | ?>
Set or return CV to CC protection
switch
:OCP
[:STATe] <Bool | ?>
Set or return over-current protection
switch
:LEVel <NRf | ?>
Set or return over-current protection
level
:OPP
[:STATe] <Bool | ?>
Set or return over-power protection
switch
:LEVel <NRf | ?>
Set or return over-power protection
level
:OVP
[:STATe] <Bool | ?>
Set or return over-voltage protection
switch
:LEVel <NRf | ?>
Set or return over-voltage protection

Table of Contents