Zones
The control panel provides up to 16 separate zones of
protection. Zone programming determines the panel’s
response to open/short and tamper conditions on the
zone loop.
Areas
The control panel supports up to 4 separate areas. You
can assign all zones to a single area, or you can assign
each zone to a combination of dierent areas.
You can arm and disarm the control panel by area,
alternatively, you can arm and disarm several areas at the
same time.
Dialler
The control panel has a built-in dialler to send reports
to the receiving party (ie. Security company monitoring
station, mobile phone, SMS etc).
Keypads
You can connect a maximum of 8 fully supervised keypads
to the control panel. Proximity keypads and external
vandal resistant metal keypads (CP150B/CP151B) are also
available.
LAN Readers
External LAN readers (PR109B Black/PR110B White and
slim PR111B Black/PR112B White) feature our proprietary
40 bit transmission format and can be used to provide
alarm and or access control functionality when used on
the Solution 16i security control panel.
IP Reporting
The CM750B Ethernet Module allows you to interface the
control panel to the building’s hard wired IP connection
point using a CAT 5E connection cable. Once congured
and operating you will be able to report to monitoring
centres that support the available IP reporting formats
and to upload/download to the control panel through an
internet or intranet connection.
History Log
The control panel can store up to 256 history events from
all 4 areas. All events are stored in the log, even if they are
programmed not to report via the on-board dialler.
You can view the control panel’s history log via keypad,
or by connection of a personal computer (direct/remote)
using the Solution Link upload/download software.
Programming
You can program the control panel either by a keypad
or using a personal computer using the Solution Link
upload/download software.
Solution Link Version V1.10 or higher is required to
program this panel.

Table of Contents

Other manuals for Bosch Solution 16i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 16i and is the answer not in the manual?

Bosch Solution 16i Specifications

General IconGeneral
BrandBosch
ModelSolution 16i
CategorySecurity System
LanguageEnglish

Related product manuals