4-6
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Programming Overview
D IR EC T L IN K P R OG RA MMI NG
The panel can be programmed via the Solution Link
Upload/Download software in either Direct Link or
Remote Link modes. For Direct Link you will need a CM900
Direct Link module which connects the panels serial port
to the PC.
Once the cable is connected you will need to hold down
the default switch on the panel for 5 seconds to initiate the
programming session. See Figure 12: for the default switch
location. It is also possible to initiate the programming
session via [MENU 5-0-5] Start Direct Link.
Solution Link V1.10 or higher is required to program this
panel.
ZO NE A R RAY
The feature allows you to view the condition or status of all
zones on the panel in groups of 4 zones at a time. Use the
[] and [] keys to change the group of zones to display.
The starting zone for each group is displayed at the
beginning of the screen so you will always know which
zones you are viewing.
Use Keys [] and [] to scroll up and down the zone bank
Press [OK] or [MENU] when nished.
N= NORMAL
S = SHORTED
A= ALARM
T= TAMPER
- = DISABLED
01nSAn
Figure 38: Zone Array Showing Z1 to Z4
09-nST
Figure 39: Zone Array Showing Z9 to Z12
In the above example screens,
N = Zone 01, 04 and 10 are Normal (Sealed)
S = Zone 02 is Shorted
A = Zone 03 is in Alarm (Unsealed)
T = Zone 12 is in Tamper Alarm (Unsealed)
- = Zone 09 is Disabled (Unused)
BAS IC R E PO RT I NG R E FE RE NC E
A complete reporting template is available on the Solution
Link CD, from your distributor or from Bosch. Your base
station will need to create a specic reporting template
for this and other 2nd generation Solution panels.
Point ID Table Module Description
Ur999 Installer
Ur998 Remote User
Ur001 - 256 Users
Ur000 Quick Arm
Zn301-428 User Keyfob 1 - 128
Zn891-898 Panels 1-8
Zn881-888 Keypads 1-8
Zn871-878 Ethernet 1-8
Zn861-868 GSM 1-8
Zn851-858 Output Expander 1-8
Zn841-848 Serial Expander 1-8
Zn831-838 Lan P/Supply 1-8
Zn821-828 RF Reciever 1-8
Zn811-818 Access 1-8
Zn801-808 X10 1-8
Zn781-788 Input Expander
Zn791-798 Lift 1-8
Zn001-128 Zones
Table 19: Basic Reporting Code Reference