7-1
Bosch Security Systems 09/11 BLCC500I
S E C T IO N 7
Input Programming
T
he Solution 16i is capable of controlling up to 16 inputs
in either hardwire or wireless conguration. Each
input can have its own unique name up to 16 characters
to identify it on the system for display and reporting
purposes.
Under the commands menu you are able to view the
status of any input, bypass a zone, dene which zones will
operate in chime mode, dene which zones operate in
part 2 mode and reset smoke detectors.
There is a command called Zone Array that allows the
installer to view the condition of inputs in banks of 4. This
is extremely helpful when commissioning a system or
fault nding.
There are numerous congurations for each hardwire
input. The end of line resistor can be congured to
eliminate the need to change the end of line resistors on a
job when doing a change over. Input zones can be setup
as alarm only, alarm + tamper or even split end of line.
For normally open contacts the system is wired exactly
the same as for normally closed but there is an option
provided that inverts the sealed state of a zone.
When arming the system, all zones will be tested by default
and you may wish to turn this option o for certain zones
so that you don’t continually alert the operator during
arming.
The sensor watch feature lets you monitor zones to ensure
that they are working and detecting movement within a
determined programmable period.
Zones by default can be bypassed and you should disable
this option for zones you don’t want to be able to bypass,
for example 24hr, re, holdup or panic zone types.
The IN input is a special input that can be congured
to accept data from a number of dierent RF receiver
manufacturers or simply be used as an keyswitch input.
The tamper options congure the system behaviour for
cabinet tamper alarms and also for the cabinet tamper of
the peripheral devices.
ZONE CON FIGURATION TABL ES
Device
Address SW
1 2 3
Single EOL
Zones
Physical
Zone
Numbering
Alarm +
Tamper
Zones
Physical
Zone
Numbering
Split EOL
Zones
Physical
Zone
Numbering
Solution Panel --- 8 1 to 8 8 1 to 8 16 1 to 16
CM704B Expander OFF OFF OFF 8 9 to 16 8 9 to 16
Total Zones 16 16 16
Table 25: Zone Conguration