4-7
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Programming Overview
S YS TE M T RO U BL E E V EN T LI ST IN G
When one or more trouble events are in eect, the keypad will display the SERVICE symbol indicating that something
requires attention. The table below lists all of the system troubles or system faults which can be present on the alarm
panel.
Each trouble event that can be shown by the panel has been assigned a unique Trouble Event Number. This number
is used to identify the trouble event from the list shown in Table 20: System Trouble / Fault Descriptions” on page 4-8”
on page 4-7.
To interpret the system trouble from the keypad do the following;
1) Enter program mode and then press [7] + [0] + [1] + [OK]. Alternatively you can press the [] at any time provide a
system trouble is present. The keypad will now show the rst trouble event number in the display. Use the the [] and
[] keys to scroll from one trouble event to the next.
2) To nd out more detail on each specic trouble event you can either refer to the trouble event descriptions in the
table below or to view more specic information on the keypad press [OK] and the display will begin to scroll the
trouble event number, the device or module number, trouble text description 1 and then trouble text description 2. The
display will continure to scroll the description of the trouble event which is in focus.
3) To return to the trouble list, press the [MENU] key or the exit completely and return to normal state press and hold the
the [MENU] key down for 2 seconds.
H OW SYS T EM T RO U BL ES A RE D I SP LAY ED
The following diagram shows the typical procedure and keypad displays for a panel with 3 system troubles. The trouble
shown are Panel Tamper, Panel AC Fail and Panel Date and Time Error.
Enter programming mode and then press MENU 7-0-1 + [OK]
F40-1
Press [OK]
P001 cASE OPEn
Press [] or []
Scrolling
F41-1
Press [OK]
P001 nO AC
Press [] or []
Scrolling
F45-1
Press [OK]
P001 cLOc ErrOr
Press [] or []
Scrolling
End
Figure 40: System Trouble Display Sequence
Trouble Event Number
Trouble Event
Description
Device or
Module Number
Trouble Text
Description #1
Trouble Text
Description #2
F00-Output # Output Missing OP00x LOst
F01-Output # Output Overload OP00x LOAd Short
F02-Output # Output Trouble OP00x NO LOAd
F10-Zone # Zone Missing Zn0xx LOst
F11-Zone # Zone Tamper Zn0xx cAse Open
F12-Zone # Zone Sensor Watch Zn0xx SEnSOr ALErt
F13-Zone # Zone Low Battery Zn0xx bAttry LEvEl
F20-Zone Expander # Zone Module Expander Missing IE001 LOSt
F21-Zone Expander # Zone Module Expander Tamper IE001 cASE OPEn
F30-Keyfob # RF Keyfob User Low Battery KF0xx LO BAt
F40-Panel # Panel Tamper P001 cASE OPEn

Table of Contents

Other manuals for Bosch Solution 16i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 16i and is the answer not in the manual?

Bosch Solution 16i Specifications

General IconGeneral
BrandBosch
ModelSolution 16i
CategorySecurity System
LanguageEnglish

Related product manuals