EasyManuals Logo

Bosch Solution 16i Installation Manual

Bosch Solution 16i
154 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #76 background imageLoading...
Page #76 background image
7-12
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Input Programming
Inputs > Global Input Options > L341
Keyswitch Options
MENU 3-4-1
(*** System Wide Parameter ***)
0 0
00 = Latching - All On/O 05 = Momentary All On/O
01 = Latching - All On 06 = Momentary - All On
02 = Latching - Part On/O 07 = Momentary - Part On/O
03 = Latching - Part On 08 = Momentary - Part On
04 = Latching - O 09 = Momentary - O
This menu programs the properties for any zone in the
system programmed as a keyswitch zone. Only one
option can be selected for the entire system which means
that all keyswitches tted will behave the same way.
The system can send Open and Close reports based on the
keyswitch operation with the zone number representing
the user number in the report.
1) Enter your Installer PIN + [MENU].
2) Enter [3] + [4] + [1] + [OK]. The keypad will display
the current keyswitch options (Default = 0
Disabled).
d= 5
3) Use the numeric keys to enter the keyswitch option
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Inputs > Global Input Options > L342
Input Options
MENU 3-4-2
1 Tamper On Short N
2 Reserved N
3 Response Time 500ms N
4 Reserved N
5 Keyswitch Open / Close Y
6 Alarm On Tamper N
7 Reserved N
8 Reserved N
(*** System Wide Parameter ***)
This menu programs the various global input options
which will eect all zones on the system.
1) Enter your Installer PIN + [MENU].
2) Enter [3] + [4] + [2] + [OK]. The keypad will display
the current input options.
-Bit-
5
3) Use the keys [1] to [8] to toggle on or o the option
required.
4) Repeat Step 3 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Tamper On Short
Setting this option will cause any Zone which become
shorted to report a tamper alarm condition for the zone.
Response Time 500ms
Setting this option will increase the response time for all
zones to 500ms.
Keyswitch Open/Close
This feature allows you to select whether or not a zone
programmed as a Keyswitch Zone, will send opening and
closing reports. The default is set to O.
Alarm On Tamper
This option allows tamper circuits on RF sensors and
hardwire zones to sound an alarm when faulted when
their corresponding area is turned o (disarmed).

Table of Contents

Other manuals for Bosch Solution 16i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 16i and is the answer not in the manual?

Bosch Solution 16i Specifications

General IconGeneral
BrandBosch
ModelSolution 16i
CategorySecurity System
LanguageEnglish