Solution 16i
Installation Manual Area Programming
3) Delayed Chime (Max 255 seconds)
Will sound the chime alarm only after the chime zone(s)
has been open or faulted for the programmed time.
000ch
4) Chime Latching.
Will sound the chime alarm until a valid user code is
entered followed by the [OK] key. This will reset the Chime
Alarm.
ch LAt
To set the chime mode.
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [2] + [0] + [6] + [OK].
If your system has been congured for multiple areas,
your keypad will prompt you to enter the area number
to program. The keypad will display the current chime
mode set for that area.
3) Use the [↑] and [↓] keys to select the required chime
mode.
If a time parameter is required for the chosen mode,
simply enter the require value in seconds.
4) Press [OK] to save and exit, or press [MENU] to exit
without saving.
A RE A P R OP ER TIE S
Areas > Properties > A-nAmE
Area Name
-
MENU 2-1-0
A r e a 1 N a m e
This menu allows you to program the name for each area.
The area name can be up to 16 characters long. At factory
default, only Area 1 is used. The control panel can have a
maximum of 4 independent areas programmed.
1) Enter your Installer PIN or Master PIN + [MENU].
2) Enter [2] + [1] + [0] + [OK].
The keypad will prompt you to enter the area number
of the area that you want to change the name for.
A=
3) Enter the area number (1 to 4), then press [OK].
The keypad will display the rst six characters of the
current area name.
ArEA 1
4) Use the [0] to [9], [←] and [→] keys to change the
area name text as required.
At any time you can use the [↑] and [↓] keys to scroll
through the complete list of available characters.
To clear all text from the cursor position to the right,
press the [OFF] key.
5) When the area name is complete, press [OK] to save
and exit, or press [MENU] to exit without saving.
DEFAULT AREA NA MES
Area Number Default Name
1 Secvrity System
2 AreA 2
3 AreA 3
4 AreA 4
Table 24: Default Area Names
Areas > Properties > L211
General Options
MENU 2-1-1
1 Exit Time Restart N
2 Reset Alarm Memory On Disarm N
3 Duress Allowed Y
4 Acknowledge All Faults N
5 Single Button Arming - All On Y
6 Single Button Arming - Part On Y
7 Link To Common Area Y
8 Single Button Part O N
The above options are programmable per area.
1) Enter your Installer PIN + [MENU].
2) Enter [2] + [1] + [1] + [OK],
3) Enter the area required, then press [OK].
4) Use the keys [1] to [8] to toggle on or o the option
required.
-Bit-
3 5 6 7
5) Repeat Step 4 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.