5-1
Bosch Security Systems 09/11 BLCC500I
S E C T IO N 5
Access Programming
The Solution 16i has 48 users which can each use any
combination of pin, radio keyfob or a proximity token to
operate the system. A total of 8 proximity readers can be
connected, which are integrated within the individual
keypads.
Each user can be assigned their own unique name up to
16 characters long to identify the user within the system
and to present a greeting message when operating the
system. User PIN’s can be congured for 1 to 8 digits or
variable where users can have dierent pin lengths up to
8 digits long. All users have options which can be set to
control their authority level within the system, whether
they are allowed to bypass zones or send open close
reports see MENU 1-4-2 — User Options.
The installer Ur999 is a special user within the system and
has ultimate privileges which can not be changed. The
Installer PIN can arm or disarm the system and has access
to all menus at all times. This is a very powerful user pin
and should be treated with utmost respect so that it is not
widely known.
Timer Group
Users can belong to a timer group that determines
whether or not the user is allowed access to the system.
To create a timer group you will need to setup a schedule
with start and stop times then set the function to Timer
Group and select an index 1 to 8 to represent the timer
group. Each user that you require to be restricted is then
assigned to the timer group number you selected.
Multiple schedules can be used to create multiple access
times within the day and holiday schedules can also be
linked with schedules.
Example:
Restricting access to only Monday to Friday 8am to 10pm.
1) Pick a timer group number between 1-8 lets say 5.
2) Set up a schedule start time 8am, stop time 10pm,
days MTWTF, Function =Timer Group, Index=5
3) Assign each restricted user to Timer Group 5
Schedules
Schedules determine the valid operating times and days
and then the schedule is linked to a timer group number.
Users which are to be restricted are then assigned to the
same timer group number as the schedule.
Access Group
A user can be restricted to certain doors within a building
and this is done by assigning the user to one or more
access groups. When a user presents his token to a
proximity reader, the user parameters are checked and if
the user has a matching access group assignment to the
reader access group assignment then access is granted.
The output used to operate the door strike will also need
to have the same access group assignment number so
that it operates at the same time. To restrict a user from
accessing doors outside specied times, create a timer
group and assign the user to the timer group.
Example:
Prox reader operating a door.
1) Assign proximity reader 1 to an access group 1-8
say 4
2) Set an output Event type=Access group and
Index=4
3) Assign user to access group 4, a user can belong to
multiple access groups to access multiple doors.
4) Assign reader to area 0 and disable arm/disarm
options
5) Present token to reader to access door
Example:
Prox reader operating door and disarm Area 1.
1) Assign proximity reader 1 to an access group 1-8
say 4
2) Set an output Event type=Access group and
Index=4
3) Assign user to access group 4, a user can belong to
multiple access groups to access multiple doors.
4) Assign reader to area 1, enable arming option
5) Present token to reader to disarm, present token
again to release door.

Table of Contents

Other manuals for Bosch Solution 16i

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Bosch Solution 16i and is the answer not in the manual?

Bosch Solution 16i Specifications

General IconGeneral
BrandBosch
ModelSolution 16i
CategorySecurity System
LanguageEnglish

Related product manuals