Pulse Count Handover Allowed
This option allows zones from the same area that have
both pulse count and pulse count time programmed the
ability to hand over pulses to other pulse count zones
during their respective pulse count time. Only zones that
have an active pulse count time can accept pulse count
handover from another zone.
Burglary delay zones can only handover pulses to other
burglary delay zones. Burglary instant and/or handover
zones can handover pulses to other burglary instant and/
or handover zones. 24 hour non-re zone types can only
handover pulses to other 24 hour non re zones. A 24-
hour re zone can only handover pulses to another 24-
hour re zone.
Senior Watch
This option requires at least one burglary zone in the
corresponding area to be faulted and restored during
the senior watch time. If no burglary zone has register
during the senior watch time, the keypad will sound an
alarm.
To warn the user that senior watch time is about to
expire, the keypad will sound the auto arm pre-alert time
(if programmed) prior to sounding the alarm. See MENU
7-2-6 — Senior Watch Time.
This feature is not applicable when the corresponding
area is turned All On.
An output (Output Event Type 51) can be programmed to
operate as follow Senior Watch if required.
Reset Smoke On Arming
This option when set, will trigger any output that is
programmed as event type 49 - Smoke Sensor GND to
operate on the next arming cycle, therefore resetting the
connected smoke sensors each time the area is armed.
If this option is not set then a manual reset will need to
be performed via MENU 3-0-5.
Areas > Properties > L213
Output Options
MENU 2-1-3
1 Arm/Disarm Speaker Beeps Via RF Keyfob Y
2 Arm/Disarm Speaker Beeps Via Keyswitch Y
3 Siren / Strobe When Part On Allowed Y
4 Alarm On PIN Retry Violations Y
5 Alarm On Exit Error N
6 Alarm On Keyswitch Tamper (Only If System Armed) Y
7 Reserved N
8 Reserved N
The above options are programmable per area.
1) Enter your intstaller PIN + [MENU].
2) Enter [2] + [1] + [3] + [OK].
3) Enter the area required, then press [OK].
4) Use the keys [1] to [8] to toggle on or o the option
required, then press [OK].
-Bit-
1 2 3 4 6
5) Repeat Step 4 until all options are programmed as
required, then press [OK] to save and exit or press
[MENU] to exit without saving.
Arm/Disarm Speaker Beeps Via RF Key Fob
This option allows audible beeps via the speaker output
to verify to the user that they have successfully turned
the area On or O using the RF keyfob. The speaker
output will sound One beep for O, two beeps for On
and three beeps for Part On.
Arm/Disarm Speaker Beeps Via Keyswitch
This option allows audible beeps via the speaker output
to verify to the user that they have successfully turned
the area On or O using a Keyswitch. The speaker output
will sound One beep for O, two beeps for On.
Siren / Strobe When Part On Allowed
This option allows the strobe and audible alarms to
operate when the system is turned Part On or Part 2 On
mode.
Alarm On PIN Retry Violations
When the PIN Retry Count as programmed in MENU 1-5-
1 is reached an audible alarm will occur.
Alarm On Exit Error
This option allows you to sound an alarm when an exit
error occurs.
An exit error occurs when an entry/exit delay zone
becomes unsealled during exit delay time and remains
unsealled at the end of exit delay time. If this happens,
the entry delay will start. If the area is not turned o
(disarmed) before the entry delay time expires an alarm
will occur.
Alarm On Keyswitch Tamper
This option allows you to sound an alarm when a tamper
condition occurs on a zone programmed as a Keyswitch
Zone. Refer to Menu 3-1-1 — Zone Type in Section 8 -
Input Programming for information on programming
zones to be a keyswitch input.