7-10
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Input Programming
Siren lockout will be reset on the next arming cycle.
See MENU 7-4-3 — Swinger Siren to set the shutdown
count.
Silent Alarm
Setting this option will set the correspondiing zone to
become a silent zone. Audible alarm outputs will not
sound when a silent zone is triggered.
Inverted Seal
Setting this option allows a normally-open sensor
or device to operate as a normally-closed device by
reversing the open/closed state of the zone loop. (eg.
When the zone loop is open, the system will register the
zone loop as closed or normal.)
Bypass Allowed
Setting this option allows users with the appropriate
access level to manually bypass this zone eectively
removing it from the area for the current arming cycle.
All zone types including 24hour zones can be bypassed if
this option is selected. Bypassed zones will be reset when
the area is turned o or disarmed.
Sensor Watch
Setting this option causes the system to monitor the
zone’s activity while the corresponding area is in the
disarmed state. If the zone fails to unseal and reseal at
least once during the Sensor Watch Time period a system
trouble will be displayed on the keypad and a Sensor
Watch report for the corresponding zone will be sent to
the programmed destination. See MENU 3-9-2 — Sensor
Watch to set the time period.
Sensor Watch monitoring is only active when the
area is in the disarmed state. 24 hour zone types
cannot be monitored using the Sensor Watch feature.
Armed When In Part Mode 1
Setting this option causes the zone to be active or
monitored when the corresponding area is armed in Part
On Mode 1.
If this option is not set, the corresponding zone will be
inactive when the area is armed in Part Mode 1 allowing
users to move freely within this zone and not trigger an
alarm.
Test On Exit
Setting this option will cause the system to prompt the
user that a zone or zones are not sealled when they
attempt to arm the area in which the zone belongs.
An error beep will sound and a zone trouble message
will display on the keypad advising the user to seal the
zone(s) or to bypass them before the area will arm.
If this option is disabled the zone will not be tested
during the arming sequence and the system will arm. If
the zone(s) are unsealled at the end of exit time a Zone
Trouble report will be sent.
A DD IN G RF SE N SO RS
The Solution 16i panel supports a wide range of 3rd party
wireless movement sensors, door contacts and smoke
detectors allowing you to choose the most appropriate
devices for each installation.
There are basically two dierent methods for adding RF
devices to the Solution 16i, Direct Entry and Learn Mode.
The system will prompt for the appropriate method
depending on the Receiver type you have tted.
In all cases the RF sensor must be compatible with the RF
Receiver that is installed. See MENU 3-5-0 — Input Type.
Zones congured as RF zone will follow all other zone
properties.
RF Sensor - Direct Entry Mode
Inputs > RF Zone > L330
Add RF Device
MENU 3-3-0
This menu allows you to program an RF device to a zone.
Only one device can be connected to each zone up to a
maximum of 16 RF devices per system.
1) Enter yout Installer PIN + [MENU].
2) Enter [3] + [3] + [0] + [OK], then enter the zone
number required and press [OK].
000000
3) Using the numeric keys, enter the RF device ID
number.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
RF Sensor - Learn Mode
1) Enter yout Installer PIN + [MENU].
2) Enter [3] + [3] + [0] + [OK], then enter the zone
number required and press [OK].
000000
3) Trigger the RF device to transmit its ID number.
4) Press [OK] to save and exit or press [MENU] to exit
without saving.
Make sure that only one device is triggerred when the
system is in learn mode. Devices that have already
been learnt cannot be learnt again unless they are
deleted from the system rst.