8-5
Bosch Security Systems 09/11 BLCC500I
Solution 16i
Installation Manual Output Programming
27 – Exit Time
This event type will cause the output to operate while
Exit Timer is active. The output will reset when the exit
timer expires or the corresponding area is disarmed.
28 – End Of Exit Time
This event type will cause the output to operate
when the Exit Time expires and will reset when the
corresponding area is disarmed.
29 – Chime On
This event type will cause the output to operate when
Chime Mode is activated and will reset when Chime
Mode is turned o.
If the event assignment for this output is set to zero (all
areas), then the output will operate as soon as Chime
Mode is activated in any area and will reset when Chime
Mode is turned o in all areas.
30 - Chime Zone Faulted
This event type will cause the output to operate when
a specic Chime Zone is triggered and reset when the
Chime Zone reseals.
If the event assignment for this output is set to zero (all
areas), then the output will operate as soon as any chime
zone is triggered provided that Chime Mode is on in
those areas. The output will reset when all Chime Zones
are resealed. For this event type to work Chime Mode
must be turned on. See MENU 2-0-5 — Chime On/O
31 – Auto Arm Pre-Alert
This event type will cause the output to operate when
the Auto Arm Pre-Alert Timer is active and will reset
when the Pre-Alert Timer expires or a valid user code is
entered.
32 – Ready To Arm All On
This event type will cause the output to operate when
the area is disarmed and all zones in the area are sealled.
The output will reset when the area is armed or when a
zone becomes unsealed.
If the event assignment for this output is set to zero (all
areas), then the output will only operate if all areas are
disarmed and all zones are sealed. The output will reset if
any area is armed or if any zone becomes unsealed.
33 – Ready To Arm Part On
This event type will cause the output to operate when
the area is disarmed and all zones in the area which are
to be monitored in Part On mode are sealed. The output
will reset when the area is armed or when a Part On zone
becomes unsealled.
If the event assignment for this output is set to zero (all
areas), then the output will only operate if all areas are
disarmed and all Part On zones are sealed. The output
will reset if any area is armed or if any Part On zone
becomes unsealed.
34 – Ready To Arm Part 2 On
This event type will cause the output to operate when
the area is disarmed and all zones in the area which
are to be monitored in Part 2 On mode are sealled. The
output will reset when the area is armed or when a Part 2
On zone becomes unsealed.
If the event assignment for this output is set to zero (all
areas), then the output will only operate if all areas are
disarmed and all Part 2 On zones are sealed. The output
will reset if any area is armed or if any Part 2 On zone
becomes unsealed.
35 – ‘Close’ Report Sent OK
This event type will cause the output to operate when
the Closing report has been acknowledged (Kissed-O)
by the control room receiver. The output will reset when
the area is disarmed. If the output has been assigned to
multiple areas then it will only reset when all areas have
been disarmed.
36 – External Siren (Spk Beeps)
This event type will cause the output to operate when
any audible alarm occurs. The output will reset when the
system or area is disarmed.
This event type will also generate speaker beeps
when the system or area is armed via a RF Keyfob, the
Programmable Input Terminal or Keyswitch zone.
1 beep when the area is disarmed
2 beeps when the area is armed All On
3 beeps when the area is armed Part On
37 – Internal Siren
This event type will cause the output to operate when
any audible alarm occurs. The output will reset when
the system or area is disarmed. No speaker beeps are
generated for this event type.
38 – Alarm Any (Silent or Audible)
This event type will cause the output to operate when
any silent or audible alarm occurs. The output will reset
when the system or area is disarmed
39 – Fire Alarm
This event type will cause the output to operate when
any audible re zone or keypad emergency re alarm
occurs. The output will reset when the system or area is
disarmed.
40 – Burglary Alarm
This event type will cause the output to operate when
any audible burglary alarm (including keypad emergency
panic, medical and tamper alarm) occurs. The output will
reset when the system or area is disarmed.