App. 4-52 Confidential
WSW48
(USB setup latency)
Selector
No.
Function
Setting and Specifications
1
|
5
Not used.
6
|
8
USB setup latency
(Not used.)
No. 6 7 8
0 0 0 : Default period
0 0 1 : Shorter 1
0 1 0 : Longer 1
0 1 1 : Longer 2
1 0 0 : Longer 3
1 0 1 : Longer 4
1 0 0 : Shorter 2
1 1 1 : Shorter 3
- Selectors 6 through 8: USB setup latency (Not used.)
These selectors should not be disturbed.
WSW49 (End-of-copying beep and print in black)
Selector
No.
Function
Setting and Specifications
1
2
Not used.
0 0 : None
0 1 : 1Mbytes
1 0 : 2Mbytes
1 1 : 4Mbytes
3
Presence or absence of
copy completion sound
0: Present 1: Absent
4
5
Command flag detection
time
No. 4 5
0 0 : 150 ms
0 1 : 350 ms
1 0 : 550 ms
1 1 : 750 ms
6
7
Scanning light source
WARMUP time adjustment
<Models concerned: CCD
scanning type>
0 0 : No adjustment
0 1 : 80%
1 0 : 120%
1 1 : 150%
8 Not used.
- Selectors 4 and 5: Command flag detection time
After receiving a command flag, the machine will wait for the command that should follow for the
time length specified by these selectors.