335
TRIM AND TILT
ROUTINE INSPECTIONS
13
ROUTINE INSPECTIONS
General
Check for external signs of fluid leakage. Correct
causes as necessary.
Check the battery to be sure it is in good operating
condition.
Reservoir Fluid
Check reservoir fluid level every three years or
every 300 operating hours. System capacity is
approximately 21 fl. oz. (620 ml).
Refer to Trim and Tilt on p. 37 for filling proce-
dure.
Manual Release Valve
Check the manual release valve with a torque
wrench.
IMPORTANT: Tighten valve to a torque of 45 to
55 in. lbs. (5 to 6 N·m).
Stern Brackets
Inspect the stern brackets for binding.
Tighten starboard tilt tube nut to a torque of 45 to
50 ft. lbs. (61 to 68 N·m).
TROUBLESHOOTING
Single Piston System
Use the following guidelines to check a single pis-
ton trim/tilt unit that is not working correctly.
Cylinder Leakdown:
Manual release valve seals
External leaks
No reverse lock:
External leaks
No operation, motor runs:
Manual release valve open
Fluid level low
Pump coupler
Hydraulic pump
No tilt down:
Manual release valve
Fluid level
Slow performance:
Manual release valve
Fluid level low
Mechanical binding
Electric motor
Hydraulic pump
Unit locked in tilt up:
Mechanical binding
Hydraulic pump

Table of Contents