65
ENGINE MANAGEMENT MODULE (EMM)
DIAGNOSTIC SOFTWARE FUNCTIONS
4
Oil Control Settings
Set Oil Type
The TC-W3 oil type setting is the standard setting
for all outboards. Set TC-W3 for:
Operation with all TC-W3 outboard oils includ-
ing XD30, XD50, or XD100.
Applications requiring maximum lubrication.
Extreme applications (racing or harsh condi-
tions)
The XD100 setting provides an option to run the
outboard at a reduced oil injection rate. This set-
ting REQUIRES the use of Evinrude XD100 out-
board lubricant and is not recommended for all
applications.
Use the XD100 setting for:
Conventional use (runabouts, cruisers)
Moderate applications
Powerhead Break-In
Use the diagnostic software to initiate break-in oil-
ing. Break-in is a predetermined oiling program
that runs for five hours of outboard operation,
above 2000 RPM.
Tiller/Remote Programming
This feature controls the start in gear protection
function of the neutral switch. Tiller operated mod-
els, including remote models with an installed tiller
conversion kit, MUST be set to TILLER.
1. Oil control setting 008108
CAUTION
Running an Evinrude E-TEC outboard on
other grades of oil while set to the XD100
oil ratio will result in increased engine
wear and shortened outboard life.
1
1. Break-in oil setting 008108
1. Starter mode setting 008109
1
1