182 SECTION 55 - ELECTRICAL SYSTEM
8.13 HAZARD SWITCH
12 V should be found at this switch at all times re-
gardless of key start position.
Test procedure
8.14 HAZARD WARNING LIGHT RELAY
Operational at all times in conjunction with the haz-
ard switch.
Continuity
Pin No. Switch OFF Switch ON
1 to pin 4 -
3 - to pins 5/6/7
4 to pin 1 -
5 - to pins 2/3/6/7
6 - to pins 2/3/5/7
7 - to pins 2/3/5
Pin
No.
Hazard / Indicator
Switch OFF Switch ON
CL 12 V 12 V
+ - 12 V - 0 V - 12 V - 0 V
31 - 12 V - 0 V - 12 V - 0 V
PR - -
F28428
1: S-N
7: A/V
6: L/B
3: A-G
4: H-R
5: L/R
F 1 / C
F 2 / C
K 1 0
X C 1
X C 2
K 1 2