12 SECTION 17 - TORQUE CONVERTERS
2.7 FAULT FINDING
PROBLEM CAUSE CORRECTION
Low stall speed Hydraulic clutch not releasing
Stator support broken
Defective torque converter
Low engine power
Replace the torque converter.
Replace the torque converter.
Replace the torque converter.
Check and correct output.
High stall speed Hydraulic clutch not applying or is
slipping
Low line pressure
Sealing rings on rear input shaft
broken
Defective torque converter
Replace.
Check pump output.
Replace the seals.
Replace the torque converter.