7. Configuring through a web browser
i80 GNSS Receiver User Guide Page 85
external storage.
Start Time: Set the start time of data logging in UTC. Select Yes or
No option below to determine whether to start data logging from
the start time defined, or immediately after this session is switched
on.
Duration Time: Set the duration of data logging.
Storage: Set the storage space of this session.
Recycle Storage: Select Yes or No option to determine whether to
auto delete old files if the storage space is full.
Storage Format: Set the data format of the logged data.
FTP Push: Decide whether to push the stored files to the FTP server
of your choice.
Tap button to save the settings and back to the Log Settings
screen. Also, users can click to abandon the changed settings
and back to Log Settings screen.
Note – To modify data logging parameters, make sure the data logging
session is switched off.
To switch on or off ANY data logging session, tap the ON or OFF button to
the right of the required session.
To delete the recorded files of ANY data logging session, tap the Clear button
to the right of the required session.
To delete the recorded files of ALL data logging sessions, tap the Clear ALL
Accounts button.
7.4.2. FTP PUSH SETTINGS SUBMENU
Use this screen to configure the receiver to push stored files to the FTP
server of your choice. Only files that are configured to use FTP push are
transmitted.
Tap Modify button to the right of the required FTP server and the FTP Push
Settings screen appears: