B-3
Cisco 1240 Connected Grid Router Hardware Installation Guide
OL-26223-04
Appendix B Connector and Cable Specifications
Connector Specifications
Serial Port
For detailed information about the combination ports, see the “Router Hardware Description” chapter.
6 MOD-DEF(0) Output Grounded in SFP, indicates SFP is present
7 Rate Select
1
––
8 LOS Output Loss of Receive optical signal indicator
9VeeR GND
10 VeeR GND
11 VeeR GND
12 RD- Output Differential electrical output to PHY
13 RD+ Output Differential electrical output to PHY
14 VeeR Gnd
15 VccR 3.3V
16 VccT 3.3V
17 VeeT GND
18 TD+ Input Differential input from PHY
19 TD- Input Differential input from PHY
20 VeeT GND
1. Rate Select is an optional SFP input that controls receiver bandwidth when used with Fibre Channel applications. This pin is
unconnected.
Table B-4 SFP Port Specification (continued)
Pin Signal Name Input/Output Signal Description
Table B-5 Serial Port Specification
RS-232
1
1. The RS232 pinouts use the EIA-561 standard.
RS-485 Full Duplex RS-485 Half Duplex
Pin Signal Description (Abbreviation) DCE Signal Dir Signal Dir
1 DCE ready, ring indicator (DSR/RI) Output TX+ TX/RX+
2 Received line signal detector (DCD) Output TX- TX/RX-
3 DTE ready (DTR) Input Not used Not used
4 Signal ground (COM) COM COM
5 Received data (RxD) Output Not used Output Not used Bidirectional
6 Transmitted data (TxD) Input RX+ Input Not used
7 Clear to send (CTS) Output Not used Output Not used Bidirectional
8 Request to send (RTS) Input RX- Input Not used