EasyManua.ls Logo

Cisco 1240 - Table; Signal Description; AC Power Supply Connector; Non-Cisco Module Power Connector

Cisco 1240
216 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
B-4
Cisco 1240 Connected Grid Router Hardware Installation Guide
OL-26223-04
Appendix B Connector and Cable Specifications
Connector Specifications
AC Power Supply Connector
For detailed information about the hardware described in this section, the “Router Hardware
Description” chapter.
Non-Cisco Module Power Connector
This section provides the following information for the power connector for installing external,
non-Cisco modules on the router:
Power wiring specifications, in the “Non-Cisco Module Power Connector Specifications” in
Table B-7 on page B-4. .
Note The cable that you provide to connect the module to the 12V power connector must be wired
so that Pin 3 (cable presence) and Pin 4 (ground) are connected to each other. If they are not
connected, the module will not detect power from the router.
Power connector parts, and compatible parts, in the “Non-Cisco Module Power Connector
Specifications” in Table B-8 on page B-5.
For more information about non-Cisco modules, see the “Installing External Non-Cisco Modules”
chapter.
Table B-6 AC Power Supply Connector Specification
Pin Signal Name Signal Description
1L AC line
2 N AC neutral
3 Chassis Chassis ground
Table B-7 Non-Cisco Module Power Connector Specifications
Pin Signal Name Signal Description
1 12V 12V power from router
2 GND System ground
3 CBL_PRSENT_L Cable presence detect
4 GND System ground

Table of Contents

Related product manuals